STATUS REPORT Extraction Line Energy Spectrometer

نویسنده

  • Eric Torrence
چکیده

A measurement of the absolute collision energy with a relative precision approaching 10 is a critical component of the linear collider physics program. Measurements of the top quark and Higgs boson masses to 50 MeV can only be performed if this level of precision is achieved. The ongoing project described here will carry out the conceptual design of a downstream beam energy spectrometer capable of this level of precision, initial beam tests to validate this design, and simulation studies to show how this beam energy measurement can be combined with other available information to determine the luminosity-weighted collision energy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-resolution Laue-type DuMond curved crystal spectrometer.

We report on a high-resolution transmission-type curved crystal spectrometer based on the modified DuMond slit geometry. The spectrometer was developed at the University of Fribourg for the study of photoinduced X-ray spectra. K and L X-ray transitions with energies above about 10 keV can be measured with an instrumental resolution comparable to their natural linewidths. Construction details an...

متن کامل

In situ calibration of an extreme ultraviolet spectrometer for attosecond transient absorption experiments.

We report a method for calibrating an extreme ultraviolet spectrometer based on a flat-field grazing incidence spherical grating in the energy range of 20-30 eV. By measuring absorption lines corresponding to singly excited states in helium atoms and autoionizing states in argon atoms, the photon energy of the detected light was determined. The spectral resolution of the spectrometer, 60 meV, w...

متن کامل

Numerical optimization of spherical variable-line-spacing grating X-ray spectrometers

Operation of an X-ray spectrometer based on a spherical variable-line-spacing (VLS) grating is analyzed using dedicated ray-tracing software allowing fast optimization of the grating parameters and spectrometer geometry. The analysis is illustrated with optical design of a model spectrometer to deliver a resolving power above 20400 at a photon energy of 930 eV (Cu L-edge). With this energy take...

متن کامل

The next Linear Collider Extraction Line Design

The two main functions of the NLC extraction line include: 1) transmission of the outgoing disrupted beam and secondary particles to the dump with minimal losses; and 2) beam diagnostics and control. In this report, we describe the extraction line optics, present the results of tracking studies, and discuss the extraction line instrumentation. Presented at the 1999 IEEE Particle Accelerator Con...

متن کامل

Analysis of Aeolian Vibrations of Transmission Line Conductors and Extraction of Damper Optimal Placement with a Comprehensive Methodology

Energy balance method is an effective and simple method which is used in the amplitude calculation of Aeolian vibration in transmission lines with Stockbridge damper. However, the accuracy of the results obtained by this method, heavily depends on the assumed mode shapes of the conductor vibration. In this study, by considering an appropriate model for the conductor vibration, a comprehensive m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006