Daily CT measurement of needle applicator displacement during multifractionated high-dose-rate interstitial brachytherapy for postoperative recurrent uterine cancer.
نویسندگان
چکیده
We investigated daily needle applicator displacement during multifractionated high-dose-rate interstitial brachytherapy (HDR-ISBT) for postoperative recurrent uterine cancer. Eight patients with postoperative recurrent uterine cancer received HDR-ISBT with or without external beam radiotherapy using our unique ambulatory technique. To analyze displacement, we obtained daily computed tomography (CT) images for 122 flexible needle applicators at 21, 45, 69, and 93 hours after implantation. Displacement was defined as the length between the center of gravity of titanium markers and the needle applicator tips along the daily CT axis. For cases in which displacement was not corrected, we also calculated the dose that covered 90% of the clinical target volume (D90(CTV)) using a dose-volume histogram (DVH). Median caudal needle applicator displacement at 21, 45, 69, and 93 hours was 3, 2, 4, and 5 mm, respectively. More than 15 mm displacement was observed for 2% (2 of 122) and 17% (10 of 60) of needle applicators at 21 and 93 hours, respectively. Cases in which dwell positions were not changed to correct the treatment plan, 2 of 8 patients showed more than 10% reduction in D90(CTV) values compared with the initial treatment plan. Correction of dwell positions of the treatment source improves treatment DVH for multifractionated HDR-ISBT.
منابع مشابه
Assessment of daily needle applicator displacement during high-dose-rate interstitial brachytherapy for prostate cancer using daily CT examinations.
To improve treatment conformity for prostate cancer, we investigated daily applicator displacement during high-dose-rate interstitial brachytherapy (HDR-ISBT). Thirty patients treated with HDR-ISBT as monotherapy were examined. All patients received a treatment dosage of 49 Gy per 7 fractions over 4 days. For dose administration, we examined 376 flexible applicators (1128 points) using our uniq...
متن کامل3D image-based adapted high-dose-rate brachytherapy in cervical cancer with and without interstitial needles: measurement of applicator shift between imaging and dose delivery
PURPOSE Using 3D image-guided adaptive brachytherapy for cervical cancer treatment, it often means that patients are transported and moved during the treatment procedure. The purpose of this study was to determine the intra-fractional longitudinal applicator shift in relation to the high risk clinical target volume (HR-CTV) by comparing geometries at imaging and dose delivery for patients with ...
متن کاملCalculation of absorbed dose rate in the lungs, ribs and skin by the mammosite applicator in breast cancer brachytherapy with MCNP
Introduction: Breast cancer is the most common cancer among women. Brachytherapy is one of the ways to treat breast cancer. In brachytherapy treatments, high-dose sources are used in interstitial placement. Here, Iridium-192 is used. This source emits gamma rays with energies ranging from 136 kV to 1060 kV electron volts. The activity of the used spring is 10 Ci. The simulated ...
متن کاملApplicator Attenuation Effect on Dose Calculations of Esophageal High-Dose Rate Brachytherapy Using EDR2 Film
Introduction Interaluminal brachytherapy is one of the important methods of esophageal cancer treatment. The effect of applicator attenuation is not considered in dose calculation method released by AAPM-TG43. In this study, the effect of High-Dose Rate (HDR) brachytherapy esophageal applicator on dose distribution was surveyed in HDR brachytherapy. Materials and Methods A cylindrical PMMA phan...
متن کاملDosimetric evaluation of a novel high dose rate (HDR) intraluminal / interstitial brachytherapy applicator for gastrointestinal and bladder cancers
High dose rate (HDR) brachytherapy is one of the accepted treatment modalities in gastro-intestinal tract and bladder carcinomas. Considering the shortcoming of contact brachytherapy routinely used in gastrointestinal tract in treatment of big tumors or invasive method of bladder treatment, an intraluminal applicator with the capability of insertion into the tumor depth seems to be useful. This...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of radiation research
دوره 53 2 شماره
صفحات -
تاریخ انتشار 2012