Local measurements of viscoelastic moduli of entangled actin networks using an oscillating magnetic bead micro-rheometer.

نویسندگان

  • F Ziemann
  • J Rädler
  • E Sackmann
چکیده

A magnetically driven bead micro-rheometer for local quantitative measurements of the viscoelastic moduli in soft macromolecular networks such as an entangled F-actin solution is described. The viscoelastic response of paramagnetic latex beads to external magnetic forces is analyzed by optical particle tracking and fast image processing. Several modes of operation are possible, including analysis of bead motion after pulse-like or oscillatory excitations, or after application of a constant force. The frequency dependencies of the storage modulus, G'(omega), and the loss modulus, G''(omega), were measured for frequencies from 10(-1) Hz to 5 Hz. For low actin concentrations (mesh sizes epsilon > 0.1 micron) we found that both G'(omega) and G''(omega) scale with omega 1/2. This scaling law and the absolute values of G' and G'' agree with conventional rheological measurements, demonstrating that the magnetic bead micro-rheometer allows quantitative measurements of the viscoelastic moduli. Local variations of the viscoelastic moduli (and thus of the network density and mesh size) can be probed in several ways: 1) by measurement of G' and G'' at different sites within the network; 2) by the simultaneous analysis of several embedded beads; and 3) by evaluation of the bead trajectories over macroscopic distances. The latter mode yields absolute values and local fluctuations of the apparent viscosity eta(x) of the network.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid stiffening of integrin receptor-actin linkages in endothelial cells stimulated with thrombin: a magnetic bead microrheology study.

By using magnetic bead microrheology we study the effect of inflammatory agents and toxins on the viscoelastic moduli of endothelial cell plasma membranes in real time. Viscoelastic response curves were acquired by applying short force pulses of ~500 pN to fibronectin-coated magnetic beads attached to the surface membrane of endothelial cells. Upon addition of thrombin, a rapid stiffening of th...

متن کامل

Slow filament dynamics and viscoelasticity in entangled and active actin networks.

This paper deals with correlations between the viscoelastic impedance of entangled actin networks and the slow conformational dynamics and diffusive motions of single filaments. The single filament dynamics is visualized and analysed by analysing the Brownian motion of attached colloidal beads, which enables independent measurements of characteristic viscoelastic response times such as the enta...

متن کامل

Micro squeeze flow rheometer for high frequency analysis of nano-litre volumes of viscoelastic fluid

In this paper, the design, fabrication and experimental analysis of a piezoelectrically actuated micro squeeze flow rheometer is presented. Being only 30x30x0.5 mm in size, the micro rheometer is sensitive to very small volumes of the order of 1-10 nano-litre of liquid and light enough to operate at frequencies in the kHz regime, an order of magnitude higher than normally attainable with conven...

متن کامل

Diffusing wave spectroscopy microrheology of actin filament networks.

Filamentous actin (F-actin), one of the constituents of the cytoskeleton, is believed to be the most important participant in the motion and mechanical integrity of eukaryotic cells. Traditionally, the viscoelastic moduli of F-actin networks have been measured by imposing a small mechanical strain and quantifying the resulting stress. The magnitude of the viscoelastic moduli, their concentratio...

متن کامل

Design of a 1 DOF MEMS motion stage for a parallel plane geometry rheometer.

Rotational rheometers are used to measure paste properties, but the test would take too long to be useful for quality control (QC) on the job site. In this paper, a new type of rheometer is proposed based on a one degree of freedom (DOF) micro-electro-mechanical systems (MEMS)-based motion stage. Preliminary data will be presented to show the capability of the system to measure the viscoelastic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biophysical journal

دوره 66 6  شماره 

صفحات  -

تاریخ انتشار 1994