Evaluation of metal migration and determination of trace metals after microwave digestion for lithographic materials.
نویسندگان
چکیده
The radioactive tracer technique was applied to investigate the migration of cesium and zinc impurities from bottom antireflective coating (BARC) and photoresist (PR) into underlying substrate. The effects of normal baking temperatures and substrate types were studied. Our results indicated that BARC has higher migration ratios than PR, irrespective of the substrate types and normal baking temperatures. The substrate type did not appear to strongly affect the metal migration ratios. However, water and/or solvent evaporation due to temperature change was found to have a significant effect on metal migration. The diffusion profiles of BARC and PR were depicted based on diffusion equations and the migration ratios. Both the UV/visible spectrometric and the gravimetric methods were successfully implemented to evaluate the feasibility of closed-vessel microwave digestion efficiency for BARC and PR samples. By following the established microwave digestion method and the inductively coupled plasma mass spectrometer (ICPMS) determination, the detection limits obtained for multielements were in the ppb and sub-ppb levels. Except for calcium, the spike recoveries of metals ranged from 91 to 132% and 87 to 125% for BARC and PR, respectively. The analytical results were found to be in reasonably good agreement with the literature values.
منابع مشابه
Determination of Metal Contents in Edible Vegetable Oils Produced in Iran Using Microwave-assisted Acid Digestion
The concentration of heavy metals in vegetable oils is an important criterion for the assessment of oil qualities with regard to freshness, keeping properties, storage and their influence on human nutrition and health. Trace heavy metals in vegetable oils are known to have an effect on the rate of oil oxidation. In this work, the contents of lead (Pb), cadmium (Cd), nickel (Ni), manganese (Mn),...
متن کاملDetermining Total Mercury in Samples from the Persian Gulf and theCaspian Sea: Comparison of Dry Ash and Wet Extraction Mothods
Monitoring of mercury in environmental samples, with its proven toxicity on the food chain, requires sensitive and accurate analytical techniques. In this study, two methods for identification and quantification of total mercury in biological and sediment samples are compared: i) dry ash preparation and subsequent established procedures for Combustion Atomic Absorption Spectrometry, (AMA 254) ...
متن کاملDetermination of heavy metals and rare earth elements in environmental samples by ICP-MS after solid phase preconcentration with chelating resin fibers and anion exchanger filters.
A solid phase collection/concentration method using anion exchanger filters and a small syringe packed with chelating resin fibers is adopted as a preconcentration tool for trace elements and a separation tool for matrices in aqueous samples prior to the measurement by inductively coupled plasma-mass spectrometry (ICP-MS). The effects of fiber volume, sample volume, eluent volume, and sample fl...
متن کاملDetermination of Metal Contents in Edible Vegetable Oils Produced in Iran Using Microwave-assisted Acid Digestion
The concentration of heavy metals in vegetable oils is an important criterion for the assessment of oil qualities with regard to freshness, keeping properties, storage and their influence on human nutrition and health. Trace heavy metals in vegetable oils are known to have an effect on the rate of oil oxidation. In this work, the contents of lead (Pb), cadmium (Cd), nickel (Ni), manganese (Mn),...
متن کاملComparison of the Levels of Five Heavy Metals in Human Urine and Sweat after Strenuous Exercise by ICP-MS
Inductively coupled plasma mass spectrometry (ICP-MS) was used to measure the levels of trace heavy metals in human urine and sweat, to compare the performance of ICP-MS using three sample processing methods, namely direct dilution, wet digestion, and microwave digestion. The results showed that the wet digestion ICP-MS method has the highest accuracy (relative standard deviation ≤10%) and is m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 71 23 شماره
صفحات -
تاریخ انتشار 1999