Characterization of plaque components and vulnerability with intravascular ultrasound elastography.

نویسندگان

  • C L de Korte
  • A F van der Steen
  • E I Cépedes
  • G Pasterkamp
  • S G Carlier
  • F Mastik
  • A H Schoneveld
  • P W Serruys
  • N Bom
چکیده

Intravascular ultrasound elastography is a method for measuring the local elastic properties using intravascular ultrasound (IVUS). The elastic properties of the different tissues within the atherosclerotic plaque are measured through the strain. Knowledge of these elastic properties is useful for guiding interventional procedures (balloon dilatation, ablation) and detection of the vulnerable plaque. In the last decade, several groups have applied elastography intravascularly with various levels of success. In this paper, the approaches of the different research groups will be discussed. The focus will be on our approach to the application of intravascular elastography. Elastograms were acquired in vitro and in vivo using the relative local displacements between IVUS images acquired at two levels of intravascular pressure with a 30 MHz mechanical or a 20 MHz array echo catheter. These displacements were estimated from the time shift between gated radiofrequency echo signals using cross-correlation algorithms with interpolation around the peak. Experiments on gel-based phantoms mimicking atherosclerotic vessels demonstrated the capability of elastography to identify soft and hard tissues independently of the echogenicity contrast. In vitro experiments on human arteries have demonstrated the potential of intravascular elastography to identify different plaque types based on their mechanical properties. These plaques could not be identified using the IVUS image alone. In vivo experiments revealed that reproducible elastograms could be obtained near end-diastole. Partial validation using the echogram was performed. Intravascular elastography provides information that is frequently unavailable or inconclusive from the IVUS image and which may therefore assist in the diagnosis and treatment of atherosclerotic disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of plaque components with intravascular ultrasound elastography in human femoral and coronary arteries in vitro.

BACKGROUND The composition of plaque is a major determinant of coronary-related clinical syndromes. Intravascular ultrasound (IVUS) elastography has proven to be a technique capable of reflecting the mechanical properties of phantom material and the femoral arterial wall. The aim of this study was to investigate the capability of intravascular elastography to characterize different plaque compo...

متن کامل

Characterizing vulnerable plaque features with intravascular elastography.

BACKGROUND In vivo detection of vulnerable plaques is presently limited by a lack of diagnostic tools. Intravascular ultrasound elastography is a new technique based on intravascular ultrasound and has the potential to differentiate between different plaques phenotypes. However, the predictive value of intravascular elastography to detect vulnerable plaques had not been studied. METHODS AND R...

متن کامل

Intravascular ultrasound elastography in human arteries: initial experience in vitro.

Intravascular elastography is a new technique to obtain the local mechanical properties of the vessel wall and its pathology using intravascular ultrasound (IVUS). Knowledge of these mechanical properties may be useful for guiding interventional procedures. An experimental set-up is described for assessment of the strain data of arteries. Using a 30-MHz IVUS catheter, radio frequency data are a...

متن کامل

Identification of atherosclerotic plaque components with intravascular ultrasound elastography in vivo: a Yucatan pig study.

BACKGROUND Intravascular ultrasound elastography assesses the local strain of the atherosclerotic vessel wall. In the present study, the potential to identify different plaque components in vivo was investigated. METHODS AND RESULTS Atherosclerotic external iliac and femoral arteries (n=24) of 6 Yucatan pigs were investigated. Before termination, elastographic data were acquired with a 20-MHz...

متن کامل

Shear wave elastography plaque characterization with mechanical testing validation: a phantom study.

Determining plaque vulnerability is critical when selecting the most suitable treatment for patients with atherosclerotic plaque. Currently, clinical non-invasive ultrasound-based methods for plaque characterization are limited to visual assessment of plaque morphology and new quantitative methods are needed. In this study, shear wave elastography (SWE) was used to characterize hard and soft pl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 45 6  شماره 

صفحات  -

تاریخ انتشار 2000