Effective source mismatch uncertainty evaluation using resistive power splitter up to 18 GHz
نویسندگان
چکیده
CSIR-National Physical Laboratory (NPL) India is a National Metrology Institute (NMI), which disseminate traceability of the physical parameters in the country. In the field of microwave, it is one of the apex laboratories to provide traceability. In this paper, the method for precession measurement of effective source reflection coefficient using resistive power splitter and mismatch uncertainty evaluation are reported and discussed. Juroshek method is implemented in conjunction with Vector Network Analyzer (VNA) for mismatch uncertainty evaluation by measuring source reflection coefficient from measured S parameters. The measurement results and their associated uncertainty are presented and discussed from 1 MHz to 18 GHz of the resistive power splitter. The complex reflection coefficient of the effective source is determined using indigenously developed automation software. The method adopted is the most convenient way of measuring effective source reflection coefficient whose values are smaller than the manufacturer specs. The mismatch uncertainty has been improved, which is beneficial during the calibration of power sensors along with power meters.
منابع مشابه
A Novel Resistive Capacitive Feedback Trans-impedance Amplifier Optimization Using IPSO Algorithm
A novel low noise trans-impedance amplifier is proposed using low cost 0.18 µm CMOS technology. A resistive-capacitive feedback is used to extend the bandwidth of the amplifier. As the structure is inductor less, it is suitable for low cost integrated optical interconnects. In this paper Improved Particle Swarm Optimization have applied to determine optimal trans-resistance and noise of propose...
متن کاملAll-Optical Reconfigurable-Tunable 1×N Power Splitter Using Soliton Breakup
In this paper, we numerically simulated a glass-based all-optical 1×N power splitter with eleven different configurations using soliton breakup in a nonlinear medium. It is shown that in addition to reconfigurability of the proposed splitter, its power splitting ratio is tunable up to some extent values too. Nonlinear semivectorial iterative finite difference beam propagation method (IFD-...
متن کاملBalunikum active phase splitter test IC
The Balunikum IC includes two phase splitters for the frequency range of 1-30 GHz. It proved that one of the two operates well. At 30 GHz the simulated mismatch between the two outputs is 0.8 dB and 6.5 degrees. The circuit is realised in the QUBiC4X IC process. The power consumption of the test circuit was measured to be 27 mA from a 3V supply. Conclusions:-A test IC with two phase splitters w...
متن کاملEvaluation of Uncertainties of the Null-Balanced Total-Power Radiometer System NCSl
National Institute of Standards and Technology, Boulder. CO 80303-3328 Standard unrertaintjes are evaluated for the nuU-balarced, total-power, heicrodyned radiometer system with a switched input that was recently developed U NIST lo calibrate thermal noise sources. Eighi significant sources of uncertainty due tw sysletoatic effects arc iiicnlirtcd. two attributable to the two noise standards, a...
متن کاملMeasurement Method for Determining the Equivalent Reflection Coefficient of Directional Couplers and Power Splitters
A measurement method presented by John R. Juroshek (NIST) in conjunction with the Vector Network Analyzers R&S ZVM or R&S ZVK from Rohde & Schwarz allows fast and accurate determination of the equivalent reflection coefficient of power splitters or directional couplers. If the magnitude and phase of reflection coefficients of source (e.g. power splitter) and sink (e.g. power meter) are known, a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -