Evaluation of mouse red blood cell and platelet counting with an automated hematology analyzer

نویسندگان

  • Teruko FUKUDA
  • Eri ASOU
  • Kimiko NOGI
  • Kazuo GOTO
چکیده

An evaluation of mouse red blood cell (RBC) and platelet (PLT) counting with an automated hematology analyzer was performed with three strains of mice, C57BL/6 (B6), BALB/c (BALB) and DBA/2 (D2). There were no significant differences in RBC and PLT counts between manual and automated optical methods in any of the samples, except for D2 mice. For D2, RBC counts obtained using the manual method were significantly lower than those obtained using the automated optical method (P<0.05), and PLT counts obtained using the manual method were higher than those obtained using the automated optical method (P<0.05). An automated hematology analyzer can be used for RBC and PLT counting; however, an appropriate method should be selected when D2 mice samples are used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Producing accurate platelet counts for platelet rich plasma: validation of a hematology analyzer and preparation techniques for counting.

Platelet rich plasma (PRP) has been shown to clinically accelerate healing of both soft and hard tissues. As a result, it has gained increasing popularity. However, the clinical effectiveness of each type of PRP preparation method can vary in technique and efficiency, and current methods to evaluate the platelet concentration efficiency of PRP systems have several limitations. Therefore, the pu...

متن کامل

An Overview on: The Red Blood Cell Histogram

The RBC histogram is an integral part of automated hematology analysis and is now routinely available on all automated cell counters. This histogram and other associated complete blood count (CBC) parameters have been found abnormal in various hematological conditions and may provide major clues in the diagnosis and management of significant red cell disorders. In addition, it is frequently use...

متن کامل

Validation of Platelet Counting Accuracy With the Celltac F Automated Hematology Analyzer

Rapid and accurate analysis of platelet count plays an important role in evaluating hemorrhagic status. Therefore, we evaluated platelet counting performance of a hematology analyzer, Celltac F (MEK-8222, Nihon Kohden Corporation, Tokyo, Japan), that features easy use with low reagent consumption and high throughput while occupying minimal space in the clinical laboratory. All blood samples wer...

متن کامل

Development and Evaluation of a Novel In-Clinic Automated Hematology Analyzer, ProCyte Dx, for Canine Erythrocyte Indices, Leukogram, Platelet Counts and Reticulocyte Counts

A novel hematology analyzer for small animal medicine, ProCyte Dx, was developed from combination of the fluorescence laser flow cytometry and laminar flow impedance technologies, and its accuracy was evaluated by comparing with the conventional impedance-based hematology analyzer, pocH-100iV Diff, or microscopic manual cell counting methods with staining blood smears in the canine blood. Blood...

متن کامل

تفسیر هیستوگرام‏های اریتروسیتی به‌دست‌آمده از دستگاه‏های خودکار هماتولوژی در بیماری‏های خونی معمول

Background: Presently, the graphical data of blood cells (histograms and cytograms or/ scattergrams) that they are usually available in all modern automated hematology analyzers are an integral a part of automated complete blood count (CBC). To find incorrect results from automated hematology analyzer and establish the samples that require additional analysis, Laboratory employees will use thos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 79  شماره 

صفحات  -

تاریخ انتشار 2017