Water tank is used extensively for storing water, inflammable liquids and other chemicals. Generally, to provide water at large, tank is supported on frame or shaft (a vertical cylindrical shell). The staging with a single row of columns placed straight (vertical) along the periphery of circle or shaft, are generally adopted for elevated water tanks to support the tank container. Apart from verticality of staging, tapered (inclined) staging are also used to support the tank container. The aim of this paper is to understand the behavior of elevated water tank with frame and shaft type tapered staging in lateral earthquake loading using GSDMA guide line [6] and software SAP2000 [8]. The study have been assess, the optimum diameter of staging with reference to the diameter of container, and observed effect of staging batter. The study reveals that value of axial tension decreases with increase in tapering of staging as well as increase in diameter of staging. Optimum dimension of staging to fulfill the requirement of 'No Tension in column’ is with 70% and 80% diameter of staging in comparison with the container diameter for frame and shaft type staging respectively, in accordance with inclination of 6°. Keywords— Water, Intze Tank, Tapered Staging, Two mass model, Sloshing height
منابع مشابه
Direct Displacement Based Design of Reinforced Concrete Elevated Water Tanks Frame Staging
Elevated water tanks supported by the reinforced concrete (RC) Staging are classified as inverted pendulum structures. These are considered as structures of high post-earthquake importance and should remain functional after the seismic events. National codes of various countries recommend Force-Based Design (FBD) procedure for water tank staging, which does not ensure nonlinear performance leve...
متن کاملSeismic Behavior Assessment of Concrete Elevated Water Tanks
Elevated tanks are very important structures and consist of various types. Water supply is vital to control fires during earthquakes. Also they are utilized to store different products, like petroleum supplies in cities and industrial zones. Damage to these structures during strong ground motions may lead to fire or other hazardous events. Elevated tanks should stay functional after and before ...
متن کاملImproving seismic performance of elevated cylindrical water storage tanks using nonlinear isolators incorporating liquid–structure interaction
Pervasive construction of elevated liquid tanks as the most important sources for urban hygienic water, and their failure under earthquake, highlighs the necessity for research toward new passive control devices. Design and use of base-isolation systems for elevated liquid tanks is propounded as a novel seismic engineering technology. To date, no special examination has been discussed in relati...
متن کاملSeismic Behavior Evaluation of Concrete Elevated Water Tanks
Elevated tanks are important structures in storing vital products, such as petroleum products for cities and industrial facilities, as well as water storage. These structures have various types and are constructed in a way that a greater portion of their weight is concentrated at an elevation much about the base. Damage to these structures during strong ground motions may lead to fire or other ...
متن کاملمدل سازی رفتار دینامیکی مخازن هوایی ذخیره سیال تحت بار انفجاری
In the present study, three dimensional (3D) finite element (FE) simulations of a steel water storage elevated tank for different tank aspect ratios, percentages of water stored in the tank, tank wall thicknesses and effect of baffle in tank have been performed using the FE software ABAQUS. The coupled Euler–Lagrange (CEL) formulation in ABAQUS has been adopted herein which has the ...