In Situ High Temperature Heat Flux Sensor Calibration

نویسندگان

  • Clayton A. Pullins
  • Tom E. Diller
چکیده

Recent advances in heat flux measurement have resulted in the development of a robust thermopile heat flux sensor intended for use in extreme thermal environments. The High Temperature Heat Flux Sensor (HTHFS) is capable of simultaneously measuring thermopile surface temperature and heat flux at sensor temperatures up to 1000 ◦C. The need for high temperature heat flux calibration of the HTHFS has resulted in the development of a new wide angle radiation calibration system, which operates with the sensor at elevated temperatures. The temperature dependence of the sensor output over the range of 100 ◦C to 900 ◦C has been successfully characterized with acceptable uncertainty limits. The calibrated HTHFS sensitivity agrees well with a theoretical sensitivity model, suggesting that the primary cause for the sensor’s output temperature dependence is due to the change in thermal conductivity of the sensor elements with temperature.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In Situ Thermistor Calibration for Improved Measurement of Soil Temperature Gradients

Accurate measurement of soil temperature gradients is important for the estimation of soil heat flux and latent heat flux, both major components of the surface energy balance. Soil temperature gradients are commonly measured using heat-pulse sensors equipped with thermistors. In this study, individual thermistors showed absolute temperature differences on the order of 0.2°C when placed under un...

متن کامل

Design, Calibration, and Implementation of a High Temperature Heat Flux Sensor for Hypersonic Flight Research

Recent advances in heat flux measurement have produced a robust thermopile heat flux sensor intended for use in hypersonic flight research. The High Temperature Heat Flux Sensor (HTHFS) is capable of operation at sensor temperatures up to 1050°C with simultaneous measurement of thermopile surface temperature and heat flux. Customization of the sensor design allows implementation in a broad rang...

متن کامل

Transfer Calibration Validation Tests on a Heat Flux Sensor in the 51 mm High-Temperature Blackbody

Facilities and techniques to characterize heat flux sensors are under development at the National Institute of Standards and Technology. As a part of this effort, a large aperture high-temperature blackbody was commissioned recently. The graphite tube blackbody, heated electrically, has a cavity diameter of 51 mm and can operate up to a maximum temperature of 2773 K. A closed-loop cooling syste...

متن کامل

Radiative Calibration of Heat-Flux Sensors at NIST: Facilities and Techniques

We present an overview of the National Institute of Standards and Technology high temperature blackbodies, both in operation and in development, suitable for heat-flux sensor calibration. Typical results of calibrations using the transfer technique in the 25 mm Variable-Temperature Blackbody are presented to demonstrate the long-term repeatability of the calibration technique. A comparative stu...

متن کامل

Heat Flux Determination from Ultrasonic Pulse Measurements

Ultrasonic time of flight measurements have been used to estimate the interior temperature of propulsion systems remotely. All that is needed is acoustic access to the boundary in question and a suitable model for the heat transfer along the path of the pulse train. The interior temperature is then deduced from a change in the time of flight and the temperature dependent velocity factor, which ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010