Formation and reduction of streak artefacts in electron tomography

نویسندگان

  • M Cao
  • H-B Zhang
  • Y Lu
  • R Nishi
  • A Takaoka
چکیده

We have analysed the formation of streak artefacts in the reconstruction based on the filtered back projection algorithm in electron tomography (ET) and accordingly applied an adaptive interpolation technique to artefact reduction. In the adaptive interpolation to recover the missing information, the edge positions in a projection curve were tracked to reduce the interpolation error. A simulation was used to demonstrate the effectiveness of the artefact reduction. Furthermore, image reconstruction of integrated circuit specimens in the ET experiments with the ultra-high voltage electron microscope show that the strong streak artefacts can be reduced effectively by our artefact reduction technique.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimentally-Induced Metabolic Acidosis Does not Alter Aortic Fatty Streak Formation in High-Cholesterol Fed Rabbits

Objective(s)Cardiovascular disease causes a major clinical problem in patients with end stage renal disease. Since metabolic acidosis is very common in patients with end stage renal disease, we aimed to investigate the effect of experimentally-induced metabolic acidosis on serum lipid profile and aortic fatty streak (FS) formation in normal and high-cholesterol fed rabbits.Materials and Methods...

متن کامل

Application of Different methods for Reducing Radiation Dose to Breast during MDCT

The increased use of computed tomography (CT) and its high radiation dose have led to great concerns about its potential for radiation induced cancer risks. Breast is a radiosensitive tissue based on tissue weighting factors assigned by the International Commission on Radiological Protection (ICRP). Moreover, the dose is maximal on the surface of the patient. Therefore, strategies should be tak...

متن کامل

Denoising and artefact reduction in dynamic flat detector CT perfusion imaging using high speed acquisition: first experimental and clinical results.

Flat detector CT perfusion (FD-CTP) is a novel technique using C-arm angiography systems for interventional dynamic tissue perfusion measurement with high potential benefits for catheter-guided treatment of stroke. However, FD-CTP is challenging since C-arms rotate slower than conventional CT systems. Furthermore, noise and artefacts affect the measurement of contrast agent flow in tissue. Rece...

متن کامل

Reduction of metal streak artifacts in x-ray computed tomography using a transmission maximum a posteriori algorithm

A maximum a posteriori algorithm for reduction of metal streak artifacts in x-ray computed tomography is presented. The algorithm uses a Markov random field smoothness prior and applies increased sampling in the reconstructed image. Good results are obtained for simulations and phantom measurements: streak artifacts are reduced while small, line-shaped details are preserved.

متن کامل

Adaptive Noise Reduction toward Low-dose Computed Tomography

An efficient noise treatment scheme has been developed to achieve low-dose CT diagnosis based on currently available CT hardware and image reconstruction technologies. The scheme proposed includes two main parts: filtering in sinogram domain and smoothing in image domain. The acquired projection sinograms were first treated by our previously proposed Karhunen-Loeve (K-L) domain penalized weight...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 239  شماره 

صفحات  -

تاریخ انتشار 2010