Liquid-chromatographic determination of amiodarone and N-desethylamiodarone in serum.

نویسندگان

  • C N Ou
  • C L Rognerud
  • L T Duong
  • V L Frawley
چکیده

We have developed a stable and simple normal-phase liquid-chromatographic method for simultaneously measuring amiodarone and its metabolite, N-desethylamiodarone, within 8 min. The chromatographic system consists of a 15 cm x 3.9 mm Waters "Resolve" silica column and a mobile phase of ammonium sulfate (17 mmol/L, pH 6.8) and methanol (8/92 by vol), pumped at 1.8 mL/min and monitored at 254 nm. After 250 microL of serum is mixed with 100 microL of 0.36 mol/L NaH2PO4, 100 microL of the internal standard solution (L8040, 6 mg/L), and 200 microL of isopropyl ether, the mixture is vortex-mixed and centrifuged. Fifty microliters of the organic layer is injected onto the column. Relative recovery was 100% over the assay range of 0.1 to 20.0 mg/L for both compounds. Within-run and total (day-to-day) CVs were 3% and 7% for amiodarone and 5% and 8% for N-desethylamiodarone, respectively.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simplified liquid-chromatographic assay of amiodarone and desethylamiodarone after solid-phase extraction.

We describe a rapid, simplified isocratic "high-performance" liquid-chromatographic method for simultaneous measurement of the antiarrhythmic drug amiodarone and its major metabolite, desethylamiodarone, in small volumes of sera (100 microL). Compared with liquid-liquid extraction, the solid-phase method of extraction saves time and glassware and improves reproducibility for small sample volume...

متن کامل

Simultaneous Estimation of Amiodarone and Desethylamiodarone in Human Plasma by High- Performance Liquid Chromatographic Method

A high performance liquid chromatographic method is described for simultaneous estimation of amiodarone and its metabolite desethylamiodarone in plasma. After precipitation with acetonitrile, the separation of amiodarone, desethylamiodarone and internal standard was accomplished using reversed phase chromatography. The mobile phase, a combination of ammonium acetate (pH 3.5 adjusted with ortho ...

متن کامل

Effect of chronic amiodarone therapy on defibrillation energy requirements in humans.

INTRODUCTION The effect of oral amiodarone therapy on defibrillation energy requirements in patients with an implantable defibrillator has not been established. METHODS AND RESULTS Twenty-one consecutive patients with implantable biphasic waveform defibrillators underwent a step-down determination of the defibrillation energy requirement 211 +/- 12 days before and 73 +/- 22 days after initiat...

متن کامل

Microassay of amiodarone and desethylamiodarone in serum by capillary electrophoresis with head-column field-amplified sample stacking.

Binary-system capillary electrophoresis (CE) with head-column field-amplified sample stacking permits determination of amiodarone and desethylamiodarone in 20-microL serum samples. The assay is characterized by a detection limit for both compounds of 80 nmol/L and by excellent linear response over the recommended therapeutic range for amiodarone (1.5-4 mumol/L). Intra- and interday reproducibil...

متن کامل

Interrelationships between serum levels of amiodarone, desethylamiodarone, reverse T3 and the QT interval during long-term amiodarone treatment.

The interrelationships between serum levels of amiodarone, desethylamiodarone, and reverse T3, and changes in the corrected QT interval (delta QTc) were examined in 22 patients during long-term treatment with amiodarone. At 1, 3, and 6 months of follow-up, the correlation coefficient between serum levels of amiodarone or desethylamiodarone and reverse T3 ranged from 0.01 to -0.2 (p greater than...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 36 3  شماره 

صفحات  -

تاریخ انتشار 1990