External cardiac pacing using low impedance electrodes suitable for defibrillation: a comparative blinded study.

نویسندگان

  • R H Falk
  • N J Battinelli
چکیده

OBJECTIVES The objective of this study was to determine whether the threshold for successful cardiac pacing is affected by electrode impedance and whether this procedure can be successfully carried out through low impedance electrodes that are also suitable for defibrillation. BACKGROUND Reintroduced in the early 1980s, external cardiac pacing utilizes large externally placed electrodes with a high impedance, in conjunction with a stimulator capable of producing an impulse of 20 to 40 ms in duration. On the basis of empiric observation, high impedance electrodes (> 500 omega) are believed to be optimal for external cardiac pacing. Such electrodes are unsuitable for defibrillation, a technique that is most successful when impedance is low. In view of the absence of controlled data to support this recommendation, as well as the desirability of using one set of electrodes for both pacing and defibrillation, we undertook the following study. METHODS Thirty-two normal subjects underwent a total of 110 attempts at external cardiac pacing with either (or both) high or low impedance electrodes in combination with one or two commercially available external cardiac pacemakers. Each subject underwent pacing at least twice in a randomized double-blind fashion to determine the pacing threshold and level of discomfort. RESULTS Individual subjects had a wide range of pacing thresholds but did not experience any greater discomfort with one pacemaker-electrode combination than with any other. Similarly, no pacemaker-electrode combination was superior to another in terms of pacing thresholds. The mean pacing threshold was 72.5 +/- 6 mA for the 40-ms impulse/high impedance electrode combination, 78.7 +/- 6 mA for the 40-ms impulse/low impedance electrode, 73.8 +/- 7 mA for the 20-ms impulse/high impedance electrode and 77.5 +/- 7 mA for the 20-ms impulse/low impedance electrode (p = NS for all comparisons). CONCLUSIONS Contrary to previous belief, a high impedance electrode offers no advantage for external pacing in terms of either pacing threshold or discomfort level during pacing. This study demonstrates that it is feasible to perform external pacing through an electrode that is also suitable for defibrillation and suggests that a single external pacing-defibrillation electrode is all that is needed to perform these two procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Low energy defibrillation in human cardiac tissue: a simulation study.

We aim to assess the effectiveness of feedback-controlled resonant drift pacing as a method for low energy defibrillation. Antitachycardia pacing is the only low energy defibrillation approach to have gained clinical significance, but it is still suboptimal. Low energy defibrillation would avoid adverse side effects associated with high voltage shocks and allow the application of implantable ca...

متن کامل

WORKSHEET for Evidence-Based Review of Science for Emergency Cardiac Care Worksheet author(s)

Search strategy (including electronic databases searched). DRAJER: Several search strategies were used for each data base. Only those with maximal hits were considered Embase “defibrillation” AND “pads” AND “impedance” as text words (all fields): 31 hits Embase “defibrillation” AND “pads” AND [<1966-2010]/py: 85 hits PubMed “defibrillation” AND “electrode pads” as text words (all fields): 52 hi...

متن کامل

High impedance leads and safety margin. Electrical considerations based on a simplified expression of the 'paradigm'.

For physicians who are not familiar with the electrical basis of cardiac stimulation, high impedance leads previously (10 years ago) considered as bad electrodes (high voltage) are now considered as the 'epitome' of lead technology (low energy drain): clearly impedance is not a good parameter for characterizing the qualities of a pacing lead. Using a simplified approach to the electrostimulatio...

متن کامل

Electrical cardioversion of atrial fibrillation using four defibrillation patches.

A 73-year-old female patient with hypertrophic cardiomyopathy presented with angina. During catheterization, she developed atrial fibrillation with a rapid ventricular response, associated with severe haemodynamic compromise. Two transthoracic patches (pro-padz, Zoll Medical Corporation, USA) were positioned in the anterior–posterior position, but a rectilinear biphasic 200-J shock (M-series de...

متن کامل

Low-energy cardioversion with epicardial wire electrodes: new treatment of atrial fibrillation after open heart surgery.

BACKGROUND Atrial fibrillation (AF) is the most common arrhythmia after open heart surgery. Traditional treatment with a range of antiarrhythmic drugs and electrical cardioversion is associated with considerable side effects. The aim of this study was to examine the feasibility and efficacy of low-energy atrial defibrillation with temporary epicardial defibrillation wire electrodes. METHODS A...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 22 5  شماره 

صفحات  -

تاریخ انتشار 1993