Compensation for nonrigid motion using B-spline image registration in simultaneous MR-PET

نویسندگان

  • S. Chun
  • S. Cho
  • T. G. Reese
  • B. Guerin
  • X. Zhu
  • J. Ouyang
  • C. Catana
  • G. El Fakhri
چکیده

Introduction Motion correction in PET imaging has been actively researched in the PET community, however obtaining accurate motion estimation is challenging. Motion has been usually estimated from CT images in PET/CT acquisition or from the PET data themselves. However, both modalities have limited accuracy for estimating motion because CT suffers from poor soft tissue contrast while PET has poor spatial resolution. MRI tagging patterns can be used as markers which allow tracking deformations. High frequency information such as tagging patterns can improve the performance of deformation estimations in image registration [1]. We have investigated improvement to motion-corrected PET reconstruction using HARP tracking [2] in numerical simulations [3] and phantom studies. In this abstract, we report preliminary results on motion-correction in simultaneous MR-PET imaging when motion is estimated using intensity matching based B-spline image registration. A novel motion regularizer based on the topology-preserving constraint is used for the motion estimation [4]. Our results show improvement with B-spline registration over HARP motion tracking. Methods A. Data acquisition A moving phantom consisted of a container filled with a viscous gel with background activity. A balloon with several radioactive spheres (10 mm diameter, different activity ratio) was suspended in the gel. The balloon was inflated at ~1sec periods using a ventilator causing the spheres to move as well. A trigger signal was generated by a pressure monitor and sent to an integrated MR-PET scanner at our center (BrainPET prototype PET scanner operating in the bore of a 3T TIM Trio scanner; Siemens, Germany). We collected tagged MRI and PET list-mode data simultaneously. For the MRI acquisition, we used a GRE with TE = 2.41 ms, TR of 1 s, a FOV of 128x128x128 mm, and a matrix size of 128x33x32 over 3 SPAMM axes {X, Y, Z} [5]. The tagging pattern distance was 8 mm. B. Motion estimation from MR images We chose 8 phases out of the available 32 phases (8 gates for PET) and estimated motion from each phase to the first phase (reference). Cubic B-spline nonrigid motion estimation was applied to the sum of the x, y, and z direction line tagged images and the distance between adjacent B-spline control points was 4 mm in each direction. A penalty based on the sufficient condition for topology preservation encourages the local invertibility of deformations in a fast and memory-efficient way [4]. This discourages the folding of deformations and the deformed tagging patterns. The usual choice for nonrigid image registration of tagged MRI is mutual information based registration [6] because the T1 decay of tagged MRI changes the image intensity over time. For a constant 1D image and a global translation t, we can denote two images at different motion phases f1(x) = A1 + B1 cos(kx) and f2(x; t) = A2 + B2 cos(k(x-t)) where A1, A2, B1, B2, k are constants. Then for a large domain for x, it is not hard to show that we can estimate a translation t which is close to a true value by minimizing the norm of the difference between f1(x) and f2(x) with respect to t. For B-spline nonrigid image registration, large support of B-spline basis and a strong regularity condition for deformations can encourage this property. C. PET image reconstruction We used a novel list-mode Motion-Corrected Expectation-Maximization (MC-EM) PET reconstruction algorithm developed by the authors, with estimated motion modeled in the system matrix to reconstruct the list-mode PET data while correcting it for motion. Attenuation correction maps were also deformed by the estimated motion. Reconstructed images were smoothed with a Gaussian filter with 5 mm FWHM. Results Figs. (a) and (b) show the source (reference) and target tagged MR images (1 and 17 phases at slice = 64 mm). Fig. (c) shows the deformed image by the estimated motion with a weak regularization parameter in which some locally broken tagging patterns were observed. However, with a strong regularization, Fig. (d) shows the deformed image that more accurately matches patterns (not intensities) of Fig. (b). Figs. (e) and (i) are gated PET reconstructed images (using 1/8 of collected data in the reference motion phase) and Figs. (f) and (j) are un-gated reconstructed images (using all the data at all motion phases), showing spheres that are disappearing or blurred on these images. Figs. (g) and (k) are HARPcorrected PET images that show improvement in terms of SNR or motion blurring. Figs. (h) and (l) show more improvement in terms of sphere shapes using the strong regularization of Fig. (d). Our proposed method showed significant improvement over a HARP based method in terms of contrast and SNR for large motion. For one sphere in Figs. (k) and (l), the proposed method had a contrast of 3.9 and a SNR of 20.7, while a HARP based method had a contrast of 2.4 and a SNR of 14.1. Contrast and SNR of the proposed method for PET reconstruction achieved as good a result as HARP based PET reconstruction on most spheres for smaller motion. Discussion Intensity matching B-spline registration based PET motion correction achieved ~60% better contrast and ~50% better SNR, compared to a HARP based correction, in spite of the tag fading due to relaxation of the tag lines. Additional investigation will help to identify and quantify the motion tracking characteristics of these techniques that most directly affect PET reconstruction in simultaneous MR-PET. References [1] Robinson D et al., IEEE TIP 2004. [2] Osman NF et al., MRM 1999. [3] Cho S et al., IEEE NSS-MIC 2009. [4] Chun S et al., IEEE JSTSP 2009. [5] Axel L et al., Radiology 1989. [6] Ledesma-Carbayo M et al., MRM 2008.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reconstruction-Incorporated Respiratory Motion Correction in Clinical Simultaneous PET/MR Imaging for Oncology Applications.

UNLABELLED Simultaneous PET and MR imaging is a promising new technique allowing the fusion of functional (PET) and anatomic/functional (MR) information. In the thoracic-abdominal regions, respiratory motion is a major challenge leading to reduced quantitative and qualitative image accuracy. Correction methodologies include the use of gated frames that lead to low signal-to-noise ratio consider...

متن کامل

Colloquium Motion and spatial regularization designs in motion-compensated image reconstruction (MCIR): application to simultaneous PET-MR

Often medical imaging systems cannot capture ideal quality images due to their innate acquisition speeds and patient motion. Gating methods have been investigated to reduce motion artifacts, but can suffer from insufficient measurements that result in low SNR images. Motion-compensated image reconstruction (MCIR) methods based on statistical iterative image reconstruction have been studied to i...

متن کامل

A 3D MR-acquisition scheme for non-rigid bulk motion correction in simultaneous PET-MR

PURPOSE Positron emission tomography (PET) is a highly sensitive medical imaging technique commonly used to detect and assess tumor lesions. Magnetic resonance imaging (MRI) provides high resolution anatomical images with different contrasts and a range of additional information important for cancer diagnosis. Recently, simultaneous PET-MR systems have been released with the promise to provide ...

متن کامل

MRI-based nonrigid motion correction in simultaneous PET/MRI.

UNLABELLED Respiratory and cardiac motion is the most serious limitation to whole-body PET, resulting in spatial resolution close to 1 cm. Furthermore, motion-induced inconsistencies in the attenuation measurements often lead to significant artifacts in the reconstructed images. Gating can remove motion artifacts at the cost of increased noise. This paper presents an approach to respiratory mot...

متن کامل

Graphics Processing Unit-Accelerated Nonrigid Registration of MR Images to CT Images During CT-Guided Percutaneous Liver Tumor Ablations.

RATIONALE AND OBJECTIVES Accuracy and speed are essential for the intraprocedural nonrigid magnetic resonance (MR) to computed tomography (CT) image registration in the assessment of tumor margins during CT-guided liver tumor ablations. Although both accuracy and speed can be improved by limiting the registration to a region of interest (ROI), manual contouring of the ROI prolongs the registrat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009