Comparison of cerebral oximeter and evoked potential monitoring in carotid endarterectomy.
نویسندگان
چکیده
PURPOSE To assess the cerebral oximeter, which measures regional oxygen saturation (rSO2) continuously and noninvasively, as a cerebral monitor during carotid endarterectomy (CEA). The rSO2 was compared with Somatosensory Evoked Potentials (SSEPs) as an indicator for shunting and as a predictor of postoperative neurological deficits. METHODS Seventy-two consenting patients undergoing CEA with general anaesthesia were studied. Normocarbia, normothermia and normotension were maintained. Cerebral monitoring consisted of bilateral median nerve SSEPs and the INVOS 3100 cerebral oximeter with the sensor pad placed on the ipsilateral forehead. Decreases in SSEP amplitude of 50% and in rSO2 of 10% were considered clinically significant. Neurological assessment was performed at emergence from anaesthesia, 24 hr postoperatively and at discharge. The rSO2 changes were compared with SSEP changes and with neurological deficits. Statistical analysis was with chi square and analysis of variance P < 0.05 was considered significant. RESULTS During carotid artery clamping, rSO2 decreased from 72 +/- 8% to 68 +/- 9% and mean arterial blood pressure increased from 92 +/- 14 mmHg to 98 +/- 14 mmHg. In four patients, the carotid artery was shunted because of SSEP changes after cross-clamping. Five patients had > or = 10% decreases in rSO2 following clamp application. Changes in both SSEP and rSO2 occurred in two patients. Three of the four shunted patients had transient postoperative neurological deficits. One patients had a transient deficit without changes in either monitor. There were no persistent postoperative deficits. Compared with SSEPs, rSO2 had a sensitivity of 50% and a specificity of 96%. CONCLUSION Clinical experience with this evolving technology is ongoing. Its role in neurovascular procedures has yet to be established.
منابع مشابه
Comparison of near-infrared spectroscopy and somatosensory evoked potentials for the detection of cerebral ischemia during carotid endarterectomy.
BACKGROUND AND PURPOSE We sought to assess the clinical value of regional cerebral saturation (rSO2) obtained by means of the cerebral oximeter INVOS 3100A (Somanetics) in comparison to monitoring of somatosensory evoked potentials (SEP) for the reliable detection of severe cerebral ischemia requiring shunt placement in the individual patient undergoing carotid surgery under general anesthesia....
متن کاملContinuous monitoring of jugular bulb venous oxygen saturation for evaluation of cerebral perfusion during carotid endarterectomy.
In this study we examined whether continuous monitoring of jugular bulb venous oxygen saturation (SjO2) is applicable for the evaluation of cerebral hypoperfusion during carotid endarterectomy (CEA). The subjects were 25 patients who underwent elective CEA under general anaesthesia. After the carotid stump pressure (SP) was measured, SjO2 and the somatosensory evoked potentials (SEP) were monit...
متن کاملMonitoring cerebral ischemia during carotid endarterectomy and stenting
Current therapy for carotid stenosis mainly includes carotid endarterectomy and endovascular stenting, which may incur procedure-related cerebral ischemia. Several methods have been employed for monitoring cerebral ischemia during surgery, such as awake neurocognitive assessment, electroencephalography, evoked potentials, transcranial Doppler, carotid stump pressure, and near infrared spectrosc...
متن کاملEvaluation of a cerebral oximeter as a monitor of cerebral ischemia during carotid endarterectomy.
BACKGROUND Stroke is an important contributor to perioperative morbidity and mortality associated with carotid endarterectomy (CEA). This investigation was designed to compare the performance of the INVOS-3100 cerebral oximeter to neurologic function, as a means of detecting cerebral ischemia induced by carotid cross-clamping, in patients undergoing carotid endarterectomy with cervical plexus b...
متن کاملSomatosensory evoked potentials sensitivity relative to electroencephalography for cerebral ischemia during carotid endarterectomy.
BACKGROUND AND PURPOSE The relation between electroencephalographic pattern changes and cerebral ischemia during carotid endarterectomy under general anesthesia is well established. Pattern changes seen on somatosensory evoked potentials under the same conditions are reported to be more sensitive indicators of cerebral ischemia. We estimated the sensitivity and specificity of somatosensory evok...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Canadian journal of anaesthesia = Journal canadien d'anesthesie
دوره 44 10 شماره
صفحات -
تاریخ انتشار 1997