High-speed, two-photon scanning microscope.

نویسندگان

  • K H Kim
  • C Buehler
  • P T So
چکیده

We have developed a high-speed two-photon microscope with submicrometer resolution in real time. The imaging speed improvement of this system is obtained by the use of a high-speed polygonal mirror scanner. The maximum achievable scanning rate is 40 micros/line, which is approximately 100 times faster than conventional scanning microscopes. High-resolution fluorescence images were recorded in real time by an intensified CCD camera. Using this instrument, we have resolved cellular architecture in three dimensions and have monitored the movements of protozoas. More important, photodamage to biological specimens during video-rate imaging can be minimized with two-photon excitation as compared with other one-photon modalities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Two-Photon Imaging with Diffractive Optical Elements

Two-photon imaging has become a useful tool for optical monitoring of neural circuits, but it requires high laser power and serial scanning of each pixel in a sample. This results in slow imaging rates, limiting the measurements of fast signals such as neuronal activity. To improve the speed and signal-to-noise ratio of two-photon imaging, we introduce a simple modification of a two-photon micr...

متن کامل

[Fast three-dimensional two-photon scanning methods for studying neuronal physiology on cellular and network level].

INTRODUCTION Two-photon microscopy is the ideal tool to study how signals are processed in the functional brain tissue. However, early raster scanning strategies were inadequate to record fast 3D events like action potentials. AIM The aim of the authors was to record various neuronal activity patterns with high signal-to-noise ratio in an optical manner. METHOD Authors developed new data ac...

متن کامل

High resolution TCSPC lifetime imaging

Time-correlated single photon counting (TCSPC) fluorescence lifetime imaging in laser scanning microscopes can be combined with a multi-detector technique that allows to record time-resolved images in several wavelength channels simultaneously. The technique is based on a multi-dimensional histogramming process that records the photon density versus the time within the fluorescence decay functi...

متن کامل

Agitation-free multiphoton microscopy of oblique planes.

The scanning two-photon fluorescence microscope produces optically sectioned images from the focal plane. It is sometimes desirable to acquire images from other planes of the specimen that are inclined with respect to the focal plane. In this Letter, we discuss the issues concerned with acquiring such images together with the effects of the inclination angle on image resolution and sectioning s...

متن کامل

A custom confocal and two-photon digital laser scanning microscope.

We describe a custom one-photon (confocal) and two-photon all-digital (photon counting) laser scanning microscope. The confocal component uses two avalanche photodiodes (APDs) as the fluorescence detector to achieve high sensitivity and to overcome the limited photon counting rate of a single APD ( approximately 5 MHz). The confocal component is approximately nine times more efficient than our ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Applied optics

دوره 38 28  شماره 

صفحات  -

تاریخ انتشار 1999