Comparison of plastic single-use and metal reusable laryngoscope blades for orotracheal intubation during rapid sequence induction of anesthesia.

نویسندگان

  • Julien Amour
  • Frédéric Marmion
  • Aurélie Birenbaum
  • Armelle Nicolas-Robin
  • Pierre Coriat
  • Bruno Riou
  • Olivier Langeron
چکیده

BACKGROUND Plastic single-use laryngoscope blades are inexpensive and carry a lower risk of infection compared with metal reusable blades, but their efficiency during rapid sequence induction remains a matter of debate. The authors therefore compared plastic and metal blades during rapid sequence induction in a prospective randomized trial. METHODS Two hundred eighty-four adult patients undergoing general anesthesia requiring rapid sequence induction were randomly assigned on a weekly basis to either plastic single-use or reusable metal blades (cluster randomization). After induction, a 60-s period was allowed to complete intubation. In the case of failed intubation, a second attempt was performed using metal blade. The primary endpoint of the study was the rate of failed intubations, and the secondary endpoint was the incidence of complications (oxygen desaturation, lung aspiration, and oropharynx trauma). RESULTS Both groups were similar in their main characteristics, including risk factors for difficult intubation. On the first attempt, the rate of failed intubation was significantly increased in plastic blade group (17 vs. 3%; P < 0.01). In metal blade group, 50% of failed intubations were still difficult after the second attempt. In plastic blade group, all initial failed intubations were successfully intubated using metal blade, with an improvement in Cormack and Lehane grade. There was a significant increase in the complication rate in plastic group (15 vs. 6%; P < 0.05). CONCLUSIONS In rapid sequence induction of anesthesia, the plastic laryngoscope blade is less efficient than a metal blade and thus should not be recommended for use in this clinical setting.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Conflicts of interest in expert-authored practice parameters, standards, guidelines, recommendations.

1. Amour J, Le Manach YL, Borel M, Lenfant F, Nicolas-Robin A, Carillion A, Ripart J, Riou B, Langeron O: Comparison of single-use and reusable metal laryngoscope blades for orotracheal intubation during rapid sequence induction of anesthesia: A multicenter cluster randomized study. ANESTHESIOLOGY 2010; 112:325–32 2. Amour J, Marmion F, Birenbaum A, Nicolas-Robin A, Coriat P, Riou B, Langeron O...

متن کامل

Comparison of single-use and reusable metal laryngoscope blades for orotracheal intubation during rapid sequence induction of anesthesia: a multicenter cluster randomized study.

BACKGROUND Single-use metal laryngoscope blades are cheaper and carry a lower risk of infection than reusable metal blades. The authors compared single-use and reusable metal blades during rapid sequence induction of anesthesia in a multicenter cluster randomized trial. METHODS One thousand seventy-two adult patients undergoing general anesthesia under emergency conditions and requiring rapid...

متن کامل

Changes in the light intensity of the fiberoptic laryngoscope blade by steam sterilization.

BACKGROUND I investigated the effects of steam sterilization on light intensity of reusable fiberoptic laryngoscope blades. METHODS Six new reusable fiberoptic Macintosh laryngoscope blades were steam sterilized. The light intensity was measured, the tip of the blades was photographed, and the light intensity of six new plastic disposable Macintosh laryngoscope blades was also measured. RES...

متن کامل

Evaluation of intra ocular pressure and hemodynamic change following intubation with Maccoy, Macintosh and Video laryngoscope

Background & Objective: The induction of anesthesia, laryngoscopy and endotracheal intubation can be associated with adverse hemodynamic response and increased intraocular pressure. The aim of this study was to evaluate intraocular pressure and hemodynamic changes after laryngoscopy and endotracheal intubation with three methods of laryngoscopy (Macintosh, Maccoy and Video laryngoscope).Materia...

متن کامل

Comparison of Miller and Airtraq laryngoscopes for orotracheal intubation by physicians wearing CBRN protective equipment during infant resuscitation: a randomized crossover simulation study.

BACKGROUND The purpose of this study was to evaluate the performance of orotracheal intubation with the Miller laryngoscope compared with the Airtraq laryngoscope by emergency and pediatric physicians wearing CBRN-PPE type III on infant manikins with conventional airway. We hypothesized that in this situation, the orotracheal intubation with the Airtraq laryngoscope would be faster and more eff...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 104 1  شماره 

صفحات  -

تاریخ انتشار 2006