Highly accelerated single breath-hold non-contrast thoracic MRA: evaluation in a clinical population

نویسندگان

  • Ruth P Lim
  • Priscilla A Winchester
  • Mary T Bruno
  • Jian Xu
  • Pippa Storey
  • KellyAnne McGorty
  • Daniel K Sodickson
  • Monvadi B Srichai
چکیده

OBJECTIVES The objective of this study was to evaluate the performance of a highly accelerated breath-hold 3-dimensional noncontrast-enhanced steady-state free precession thoracic magnetic resonance angiography (NC-MRA) technique in a clinical population, including assessment of image quality, aortic dimensions, and aortic pathology, compared with electrocardiographically gated gadolinium-enhanced MRA (Gd-MRA). MATERIALS AND METHODS After approval from the institution board and informed consent were obtained, 30 patients (22 men; mean age, 53.4 years) with known or suspected aortic pathology were imaged with NC-MRA followed by Gd-MRA at a single examination at 1.5 T. Images were made anonymous and reviewed by 2 readers for aortic pathology and diagnostic confidence on a 5-point scale (1, worst; 5, best) on a patient basis. Image quality and artifacts were also evaluated in 10 vascular segments: aortic annulus, sinuses of Valsalva, sinotubular junction, ascending aorta, aortic arch, descending aorta, diaphragmatic aorta, great vessel origins, and the left main and right coronary artery origins. Finally, aortic dimensions were measured in each of the 7 aortic segments. The Wilcoxon signed rank test was used to compare diagnostic confidence, image quality, and artifact scores between NC-MRA and Gd-MRA. The paired Student t test and Bland-Altman analysis were used for comparison of aortic dimensions. RESULTS All patients completed NC-MRA and Gd-MRA successfully. Vascular pathologic findings were concordant with Gd-MRA in 29 of 30 (96.7%) patients and 28 of 30 (93.3%) patients for readers 1 and 2, respectively, with high diagnostic confidence (mean [SD], 4.35 [0.77]) not significantly different from Gd-MRA (4.38 [0.64]; P = 0.74). The image quality and artifact scores were comparable with Gd-MRA in most vascular segments. Notable differences were observed at the ascending aorta, where Gd-MRA had superior image quality (4.13 [0.73]) compared with NC-MRA (3.80 [0.88]; P = 0.028), and at the coronary artery origins where NC-MRA was considered superior (NC-MRA vs Gd-MRA, 3.38 [1.47] vs 2.78 [1.21] for the left main artery and NC-MRA vs Gd-MRA, 3.55 [1.40] vs 2.32 [1.16] for the right coronary artery; P < 0.05, both comparisons). The aortic dimensions were comparable, with the only significant difference observed at the ascending aorta, where NC-MRA dimension (4.05 [0.76]) was less than 1 mm smaller than that of Gd-MRA (4.12 [0.7]; P = 0.043). CONCLUSIONS Breath-hold NC-MRA of the thoracic aorta yields good image quality, comparable to Gd-MRA, with high accuracy for aortic dimension and pathology. It can be considered as an alternative to Gd-MRA in patients with relative contraindications to gadolinium contrast or problems with intravenous access.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Single breath-hold non-contrast thoracic mra using highly-accelerated parallel imaging with a 32-element coil array

PURPOSE To evaluate the feasibility of performing single breathhold three-dimensional (3D) thoracic noncontrast MR angiography (NC-MRA) using highly accelerated parallel imaging. MATERIALS AND METHODS We developed a single breathhold NC MRA pulse sequence using balanced steady state free precession (SSFP) readout and highly accelerated parallel imaging. In 17 subjects, highly accelerated nonc...

متن کامل

Evaluation and comparison of ECG-gated techniques at 1.5 T for contrast enhanced MR angiography of the thoracic aorta

Background 3D T1-weighted contrast-enhanced MRA (CE-MRA) is routinely used for non-invasive evaluation of the thoracic aorta. However, competing demands of high spatial resolution and fast (breath-hold) acquisition often preclude ECG-gating, leading to motion artifact at the aortic root. Standard Cartesian-sampled ECG-gated CE-MRA acquires 1 partition per heartbeat resulting in long scan times,...

متن کامل

Accelerated free breathing ECG triggered contrast enhanced pulmonary vein magnetic resonance angiography using compressed sensing

BACKGROUND To investigate the feasibility of accelerated electrocardiogram (ECG)-triggered contrast enhanced pulmonary vein magnetic resonance angiography (CE-PV MRA) with isotropic spatial resolution using compressed sensing (CS). METHODS Nineteen patients (59±13 y, 11 M) referred for MR were scanned using the proposed accelerated free breathing ECG-triggered 3D CE-PV MRA sequence (FOV=340×3...

متن کامل

Free Breathing Whole Heart Coronary Angiography on a Clinical Scanner in less than 4 Minutes

K. Nehrke, P. Börnert, C. Stehning, R. Winkelmann, I. Grässlin, J. Overweg, P. Mazurkewitz, T. Rozijn Philips Research Laboratories, Hamburg, Germany, University of Karlsruhe, Karlsruhe, Germany, Philips Medical Systems, Best, Netherlands Introduction Whole heart coronary MRA has become increasingly interesting over the last years [1,2]. Although, parallel imaging techniques have been employed ...

متن کامل

Breath-hold imaging of the coronary arteries using quiescent-interval slice-selective (qiss) magnetic resonance angiography - pilot study at 1.5 tesla and 3 tesla

BACKGROUND Coronary magnetic resonance angiography (MRA) is usually obtained with a free-breathing navigator-gated 3D acquisition. Our aim was to develop an alternative breath-hold approach that would allow the coronary arteries to be evaluated in a much shorter time and without risk of degradation by respiratory motion artifacts. For this purpose, we implemented a breath-hold, non-contrast-enh...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013