Solvent enhanced ion chromatography of alkaline earth and transition metal ions on porous monolithic silica

نویسندگان

  • Edel Sugrue
  • Pavel N. Nesterenko
  • Brett Paull
چکیده

The high-performance separation of alkaline earth and transition metal ions on a bare porous silica 10.0 cm× 0.46 cm monolith (Merck Chromolith Si) was achieved using solvent enhanced ion chromatography. Using acetonitrile or methanol based ammonium and sodium acetate buffered mobile phases, the effect upon cation retention of mobile phase ionic strength, organic content and pH were evaluated. Increasing mobile phase acetonitrile concentration from 60 to 80% acetonitrile resulted in 10–15-fold increases in cation retention due to reduced hydration of the metal ions and hence enhanced ion-exchange interactions with surface silanol groups. The optimised conditions for the separation of Cu(II), Cd(II), Ni(II), Co(II) and Mn(II) were found to be 80% MeCN with 10.3 mM ammonium acetate (pH 4.6). Detection of transition metal ions was obtained using post-column reaction with 4-(2-pyridylazo) resorcinol and absorbance at 510 nm. Under elevated flow conditions (up to 5 mL/min), total runs times could be reduced to under 4 min. Optimum peak efficiencies were seen at flow rates of between 1.5 and 2 mL/min and were equivalent to an average efficiency of 25,000 N/m. © 2005 Elsevier B.V. All rights reserved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigating the Effect of Ultrasonification Time on Transition from Monolithic Porous Network to Size-Tunable Monodispersed Silica Nanospheres via Stöber Method

Abstract Uniform colloidal monodispersed silica nanoparticles were synthesized via stöber method using ammonia as a basic catalyst. Field Emission Scanning Electron Microscope (FESEM) was confirmed the homogeneous nanospheres. The decrease of TEOS concentration (0.067 to 0.012 mol L-1) and an increase of H2O concentration (3 to 14 mol L-1) at 14 mol L-1 NH3 fixed accelerated the rate of h...

متن کامل

STUDY ON THE COMPLEX FORMATION BETWEEN N-PROPYLSALICYLIDENE BASED ON SILICA AS ION EXCHANGER AND SOME TRANSITION METAL IONS

N-propylsalicylidene based on silica as ion exchanger (IE) was used for the separation by complexation of Mn2+, Co2+, Ni2+, Cu2+, Hg2+, Cr3+, Fe3+, and UO22+ from their parent solutions. IE and its metal complexes are characterized by elemental analysis, electronic and infrared spectra, in addition to thermal analysis in atmospheric pressure. The mode of chelation and the proposed geometric str...

متن کامل

Coordination and Siting of Cu+ Ion Adsorbed into Silicalite-2 Porous Structure: A Density Functional Theory Study

Coordination of Cu+ ions adsorbed on plausible sites of a silicalite-2 lattice has been investigated computationally via hybrid density functional theory method at the B3LYP/6-311+G* and B3LYP/Def2-TZVP levels of theory using molecular models of the active site. The symmetrical coordination of Cu+ ions to almost five oxygen atoms of the all-silica framework in six-membered ring (6MR) sites of t...

متن کامل

Fast ion chromatography of inorganic anions and cations on a lysine bonded porous silica monolith.

A 0.46 cm x 10.0 cm silica monolith column was modified through the in situ covalent attachment of lysine (2,6-diaminohexanoic acid) groups. Due to the zwitterionic nature of the resultant stationary phase, the modified monolithic column contained both cation and anion exchange capacity. In the case of cation exchange, the capacity was found to be relatively low at between 5 and 6.5 micromoles ...

متن کامل

Use of contactless conductivity detection for non-invasive characterisation of monolithic stationary-phase coatings for application in capillary ion chromatography.

A capacitively-coupled contactless conductivity detector (C4D) has been utilised as an on-capillary detector within a capillary ion chromatograph, incorporating a reversed-phase monolithic silica capillary column semi-permanently modified with a suitable ionic surfactant. The monolithic capillary column (150 x 0.1 mm i.d.) was modified using sodium dioctyl sulfosuccinate (DOSS), an anionic surf...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005