The effects of temporal noise and retinal illuminance on foveal flicker sensitivity

نویسندگان

  • Jyrki Rovamo
  • Antti Raninen
  • Kristian Donner
چکیده

We measured foveal flicker sensitivity with and without external added temporal noise at various levels of retinal illuminance and described the data with our model of flicker sensitivity comprising: (i) low-pass filtering of the flickering signal plus external temporal and/or quantal noise by the modulation transfer function (MTF) of the retina (R): (ii) high-pass filtering in proportion to temporal frequency by the MTF of the postreceptoral neural pathways (P): (iii) addition of internal white neural noise; and (iv) detection by a temporal matched filter. Without temporal noise flicker sensitivity had a band-pass frequency-dependence at high and medium illuminances but changed towards a low-pass shape above 0.5 Hz at low luminances, in agreement with earlier studies. In strong external temporal noise, however, the flicker sensitivity function had a low-pass shape even at high and medium illuminances and flicker sensitivity was consistently lower with noise than without. At low luminances flicker sensitivity was similar with and without noise. An excellent fit of the model was obtained under the assumption that the only luminance-dependent changes were increases in the cut-off frequency (fc) and maximum contrast transfer of R with increasing luminance. The results imply the following: (i) performance is consistent with detection by a temporal matched filter, but not with a thresholding process based on signal amplitude; (ii) quantal fluctuations do not at any luminance level become a source of dominant noise present at the detector; (iii) the changes in the maximum contrast transfer reflect changes in retinal gain, which at low to moderate luminances implement less-than-Weber adaptation, with a 'square-root' law at the lowest levels; (iv) the changes of fc as function of mean luminance closely parallels time scale changes in cones, but the absolute values of fc are lower than expected from the kinetics of monkey cones at all luminances; (v) the constancy of the high-pass filtering function P indicates that surround antagonism does not weaken significantly with decreasing light level.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Flicker sensitivity and fundus appearance in pre-exudative age-related maculopathy.

PURPOSE To evaluate whether foveal flicker sensitivity and fundus appearance are good predictors of exudative age-related maculopathy (ARM) when the effects of aging, retinal illuminance, and criterion differences are controlled. METHODS Fellow eyes of monocular exudative ARM patients were tested at baseline. Seven of these eyes have now developed exudative ARM. Therefore, at baseline they we...

متن کامل

Photopic temporal processing in retinitis pigmentosa.

PURPOSE The relation between early changes in the photopic flicker electroretinogram (ERG) and photopic psychophysical changes in retinitis pigmentosa (RP) is poorly understood. Here, abnormalities in foveal and extrafoveal temporal contrast sensitivity functions (TCSFs) were studied in a group of carefully selected patients with RP who had relatively preserved macular function. The psychophysi...

متن کامل

Flicker Sensitivity as a Function of Spectral Density of External White Temporal Noise

Foveal flicker sensitivity at 0.5-30 Hz was measured as a function of the spectral density of external, white, purely temporal noise for a sharp-edged 2.5 deg circular spot (mean luminance 3.4 log phot td). Sensitivity at any given temporal frequency was constant at low powers of external noise, but then decreased in inverse proportion to the square root of noise spectral density. Without exter...

متن کامل

Flicker sensitivity and cardiovascular function in healthy middle-aged people.

OBJECTIVE To establish normative relations between measures of visual function and cardiovascular variables that are important for age-related disease, including various forms of glaucoma. METHODS Foveal flicker sensitivities, resting blood pressures and heart rates, and intraocular pressures were measured in 18 individuals aged 40 to 68 years. All subjects had 20/20 or better visual acuity i...

متن کامل

Analysis of retinal light adaptation with the flicker electroretinogram.

To study the retinal light adaptation we measured and analyzed the flicker electroretinogram response to stimuli that varied in temporal frequency, retinal illuminance, and modulation depth. The responses measured at 100% modulation showed the classic adaptation pattern, being independent of mean retinal illuminance at low temporal frequencies, consistent with Weber adaptation, and increasing i...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Vision Research

دوره 39  شماره 

صفحات  -

تاریخ انتشار 1999