Sample Preparation for Electron Probe Microanalysis—Pushing the Limits
نویسندگان
چکیده
There are two fundamental considerations in preparing samples for electron probe microanalysis (EPMA). The first one may seem obvious, but we often find it is overlooked. That is, the sample analyzed should be representative of the population from which it comes. The second is a direct result of the assumptions in the calculations used to convert x-ray intensity ratios, between the sample and standard, to concentrations. Samples originate from a wide range of sources. During their journey to being excited under the electron beam for the production of x rays there are many possibilities for sample alteration. Handling can contaminate samples by adding extraneous matter. In preparation, the various abrasives used in sizing the sample by sawing, grinding and polishing can embed themselves. The most accurate composition of a contaminated sample is, at best, not representative of the original sample; it is misleading. Our laboratory performs EPMA analysis on customer submitted samples and prepares over 250 different calibration standards including pure elements, compounds, alloys, glasses and minerals. This large variety of samples does not lend itself to mass production techniques, including automatic polishing. Our manual preparation techniques are designed individually for each sample. The use of automated preparation equipment does not lend itself to this environment, and is not included in this manuscript. The final step in quantitative electron probe microanalysis is the conversion of x-ray intensities ratios, known as the "k-ratios," to composition (in mass fraction or atomic percent) and/or film thickness. Of the many assumptions made in the ZAF (where these letters stand for atomic number, absorption and fluorescence) corrections the localized geometry between the sample and electron beam, or takeoff angle, must be accurately known. Small angular errors can lead to significant errors in the final results. The sample preparation technique then becomes very important, and, under certain conditions, may even be the limiting factor in the analytical uncertainty budget. This paper considers preparing samples to get known geometries. It will not address the analysis of samples with irregular, unprepared surfaces or unknown geometries.
منابع مشابه
In Situ Analysis of Gut Residue of Corophium Volutator (Pallas) by Electron Probe Microanalysis after Exposure to Barytes Spiked Sediments
Corophium volutator (Pallas) has been recommended by the paris Commission as one of the standard species for testing chemical used in offshore oil and gas exploration/production. In the present study, gut contents of Corophium volutator have been analysed by electron probe microanalysis (EPMA) for BaSO4 and other heavy metal impurities after exposure tto spiked sediments followin...
متن کاملThe Use of X-ray Microanalysis in the Study of Diffusion
This paper reviews the use of electron probe microanalysis, scanning electron microscopy and analytical electron microscopy in the measurement of compositional data obtained from diffusion couples. Methods to obtain x—ray spatial resolution as low as mm with the AEM are described. In addition, techniques for improving the detection and for increasing the accuracy of compositional analyses are s...
متن کاملNanoscale Crystallographic Analysis in FE-SEM Using Transmission Kikuchi Diffraction
Recent developments in SEM column design have led to the ability to produce nm spot sizes even at high probe currents [1], thus pushing the analytical techniques available in the SEM to conduct microanalysis with nanometer resolution. Although the limitations of microanalysis at these spatial resolution requirements stem from the physics of beam-specimen interaction and the volume from which th...
متن کاملProspects for Trace Analysis in the Analytical Electron-Microscope
The analytical electron microscope (AEM) uses a high energy (>100 kV) beam of electrons to generate a range of signals from a thin foil sample as shown in figure la [1,2]. Various detectors are configured in the AEM to pick up most of the generated signals (fig. lb). Microanalysis is usually performed using the characteristic x-ray signal, detected by an energy dispersive spectrometer (EDS) alt...
متن کاملElectron Probe Microanalysis (EPMA)
An electron microprobe is an electron microscope designed for the non-destructive x-ray microanalysis and imaging of solid materials. It is essentially a hybrid instrument combining the capabilities of both the scanning electron microscope (SEM) and an x-ray fluorescence spectrometer (XRF), with the added features of fine-spot focusing (~ 1 micrometer), optical microscope imaging, and precision...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 107 شماره
صفحات -
تاریخ انتشار 2002