The New Gas Stripper and Charge State Separator of the GSI High Current Injector

نویسندگان

  • W. Barth
  • P. Forck
چکیده

The GSI Unilac was upgraded as a high current injector for the SIS in 1999. Therefore, the stripping section [1] at 1.4 MeV/u, where a beam transport under highest space charge conditions and multi beam operation had to be established, was completely new designed. Results of the commissioning of the stripper section will be presented. The beam transport to the new gas stripper, and the charge state analysis under space charge conditions confirmed the calculations. A U beam coming from a MEVVA ion source and accelerated by the new injector linacwas stripped (with the expected stripping efficiency) to the charge state 28+ and successfully separated by the new spectrometer (15 degree and 30 degree kicker magnets). The transport and matching to the poststripper accelerator under highest space charge conditions was investigated with a 15 emA Ar beam. Especially space charge and charge state dependent emittance growth effects in 6d-phase space will be discussed.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Emittance Measurements at GSI UNILAC

At GSI heavy ion beams are accelerated by the UNIversal Linear ACcelerator UNILAC (see Fig. 1) and the heavy ion synchrotron SIS 18. Heavy ion beams are delivered to the High Current Injector (HSI) from two different ion source terminals: Penning type (PIG) sources for low and MUCIS/ MEVVA type sources for high beam intensities. An RFQ and two IH structures accelerate the ions from 2.2 keV/u up...

متن کامل

The Injector Systems of the Fair Project

The present GSI accelerator chain will serve as an injector for FAIR (Facility for Antiproton and Ion Research). The linear accelerator UNILAC and the heavy ion synchrotron SIS18 should deliver up to 1⋅10 U-particles/sec. In the past two years different hardware measures and a careful fine tuning of the UNILAC resulted in an 35% increase of the beam intensity to a new record of 1.25⋅10 U-ions...

متن کامل

High Current Proton Beam Operation at Gsi Unilac

A significant part of the experimental program at FAIR is dedicated to pbar physics requiring a high number of cooled pbars per hour [1]. The primary proton beam has to be provided by a 70 MeV proton linac followed by two synchrotrons. The new FAIR proton linac [2] will deliver a pulsed proton beam of up to 35 mA of 36 μs duration at a repetition rate of 4 Hz. The recent GSI heavy ion linac (UN...

متن کامل

Investigating the Effects of Inlet Conditions and Nozzle Geometry on the Performance of Supersonic Separator Used for Natural Gas Dehumidification

Supersonic separators have found extensive applications in dehumidification of natural gases since 2003. Unlike previous studies, which have investigated the inlet conditions and nozzle geometry of supersonic separators for pure fluids, the present study employed a combination of momentum, heat, and mass transfer equations along with Virial equation of state (EOS) to inspect the effect of inlet...

متن کامل

The parametric study of an electrical submersible pump rotary gas separator under two-phase flow condition

The performance of the electric submersible pump (ESP) significantly affected by Gas Void Fraction (GVF). Thus, using of a Rotary Gas Separator (RGS) is a suitable solution for this issue. The performance of the RGS is function of different parameters such as geometry of impeller, rotating speed, boundary conditions, media viscosity and GVF. In this study, the influences of GVF, viscosity, and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000