Novel Technique for Ultra-sensitive Determination of Trace Elements in Organic Scintillators

نویسندگان

  • Z. Djurcic
  • A. Piepke
  • R. Swinney
  • B. Tipton
چکیده

A technique based on neutron activation has been developed for an extremely high sensitivity analysis of trace elements in organic materials. Organic materials are sealed in plastic or high purity quartz and irradiated at the HFIR and MITR. The most volatile materials such as liquid scintillator (LS) are first preconcentrated by clean vacuum evaporation. Activities of interest are separated from side activities by acid digestion and ion exchange. The technique has been applied to study the liquid scintillator used in the KamLAND neutrino experiment. Detection limits of <2.4×10 g K/g LS, <5.5×10 g Th/g LS, and <8×10 g U/g LS have been achieved.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A NOVEL AND HIGHLY SENSITIVE CATALYTIC METHOD FOR THE DETERMINATION OF ULTRA TRACE AMOUNTS OF CERIUM WITH SPECTROPHOTOMETRIC DETECTION

Cerium (IV) has a catalytic effect on the very slow redox reaction between gallocyanine and bromate in acidic media. The reaction was monitored spectrophotometrically at 525 nm by a fixed time method of 4.0 rnin from initiation of the reaction. The decrease in absorbance at 525 nm is proportional to the Ce (IV) concentration in the range of 0.005-1.000 and 1.00-10.00 pg. ml-l. The limit of ...

متن کامل

Novel Technique for Ultra-sensitive Determination of Trace Elements in Organic Materials

A technique based on neutron activation has been developed for an extremely high sensitivity analysis of trace elements in organic materials. Organic materials are sealed in plastic or high purity quartz and irradiated at the HFIR and MITR. The most volatile materials such as liquid scintillator (LS) are first preconcentrated by clean vacuum evaporation. Activities of interest are separated fro...

متن کامل

DETERMINATION OF ULTRA-TRACE AMOUNTS OF COBALT BY ADSORPTIVE DIFFERENTIAL PULSE VOLTAMMETRY USING ACDA (2-AMINOCYCLOPENTENE- 1-DITHIOCARBOXYLIC ACID)

The present work describes a selective, rapid and sensitive method for the determination of cobalt using the adsorptive differential pulse voltammetry technique. The method is based on the accumulation of Co(II) complex with 2-aminocyclopentene-1-dithiocarboxylic acid on a hanging mercury drop electrode, followed by measurement of the current of the adsorbed complex. The effects of experimental...

متن کامل

Elimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry

A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...

متن کامل

UV-induced carbonyl generation with formic acid for sensitive determination of nickel by atomic fluorescence spectrometry.

UV-induced carbonyl generation with formic acid is used for gaseous sample introduction into an atomic fluorescence spectrometer for the determination of ultra-trace nickel. Compared with conventional carbonyl generation, no toxic gas CO is involved in this work, and volatile Ni(CO)(4) is generated with a single reagent formic acid under the irradiation of UV light (253.7nm, 15W). The reaction ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003