Rigid laryngoscope-assisted insertion of transesophageal echocardiography probe reduces oropharyngeal mucosal injury in anesthetized patients.

نویسندگان

  • SungWon Na
  • Chang Seok Kim
  • Ji Young Kim
  • Jin Seon Cho
  • Ki Jun Kim
چکیده

BACKGROUND Intraoperative transesophageal echocardiography has become a routine part of monitoring in patients with cardiac disease. However, insertion of a transesophageal echocardiography probe can be associated with oropharyngeal, esophageal, and gastric injuries. The purpose of this study was to determine whether insertion of a transesophageal echocardiography probe under direct laryngoscopic visualization can reduce the incidence of oropharyngeal mucosal injury. METHODS Eighty patients undergoing surgery with general anesthesia were randomly allocated to either the conventional group, in which the probe was inserted blindly, or the laryngoscope group, in which a rigid laryngoscope was used to visualize the passage of the probe. The incidence of oropharyngeal mucosal injury, the number of insertion attempts, and odynophagia were assessed. RESULTS There was no significant difference in demographic and hemodynamic parameters between the 2 groups. The incidence of oropharyngeal mucosal injury was higher in the conventional group than in the laryngoscope group (55% vs. 5%, P < 0.05). The incidence of odynophagia was higher in the conventional group than in the laryngoscope group (32.5% vs. 2.5%, P < 0.05). The number of insertion attempts was also higher in the conventional group than in the laryngoscope group. CONCLUSION Rigid laryngoscope-assisted insertion of the transesophageal echocardiography probe reduces the incidence of oropharyngeal mucosal injury, odynophagia, and the number of insertion attempts.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gastroesophageal perforation after intraoperative transesophageal echocardiography.

THE use of transesophageal echocardiography for intraoperative monitoring of cardiac function is increasing. Complications are rare. Oropharyngeal injury and hypopharyngeal perforation during difficult insertion of the echoprobe in anesthetized patients have been reported. [1,2] One case of perforation of the cervical esophagus in an awake patient after multiple attempts at insertion of the ech...

متن کامل

The safety of intraoperative transesophageal echocardiography: a case series of 7200 cardiac surgical patients.

UNLABELLED Transesophageal echocardiography (TEE) is an invaluable intraoperative diagnostic monitor that is considered to be relatively safe and noninvasive. Insertion and manipulation of the TEE probe, however, may cause oropharyngeal, esophageal, or gastric trauma. We report the incidence of intraoperative TEE-associated complications in a single-center series of 7200 adult cardiac surgical ...

متن کامل

McGRATH MAC video laryngoscope for insertion of a transoesophageal echocardiography probe

BACKGROUND Transoesophageal echocardiography (TOE) probe insertion in anaesthetised patients can cause pharyngeal and oesophageal injuries. Kim et al. have shown that insertion assisted by a Macintosh laryngoscope can reduce such complications but it may sometimes be difficult to observe the passage of a TOE probe. The McGRATH MAC (McGRATH) has been shown to provide a better view of the glottis...

متن کامل

[Comparison of different methods of nasogastric tube insertion in anesthetized and intubated patients].

BACKGROUND Nasogastric tube insertion may be difficult in anesthetized and intubated patients with head in the neutral position. Several techniques are available for the successful insertion of nasogastric tube. The primary aim of this study was to investigate the difference in the first attempt success rate of different techniques for insertion of nasogastric tube. Secondary aim was to investi...

متن کامل

Echocardiographic monitoring during induction of general anesthesia with a miniaturized esophageal probe.

UNLABELLED Standard transesophageal echocardiography (TEE) does not allow cardiac monitoring during the induction of anesthesia because standard probes would limit the oropharyngeal space and impair mask ventilation and tracheal intubation. We hypothesized that a prototype, miniaturized TEE probe could be safely introduced transnasally in awake patients and that mask ventilation and orotracheal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesiology

دوره 110 1  شماره 

صفحات  -

تاریخ انتشار 2009