A fast, simple calibration method for organic carbon isotope analysis using continuous-flow elemental analyzer interfaced with an isotope ratio mass spectrometer.

نویسندگان

  • Yeon-Sik Bong
  • Kwang-Sik Lee
چکیده

Continuous flow analysis using an elemental analyzer interfaced with an isotope ratio mass spectrometer (EA-IRMS) is faster and requires much less material than conventional analytical methods. Although using an EA-IRMS is simple and fast, accurate calibration strongly depends on matching sample and reference peak heights by adjusting the sample weight. This paper describes a new modification for calibration using only the major ion beam intensity (nA) without weighing each sample or increasing the number of reference materials.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isotopic ((13)C) analysis of dissolved organic carbon in stream water using an elemental analyzer coupled to a stable isotope ratio mass spectrometer.

A technique for measurement of the stable isotope composition of dissolved organic carbon (DOC) in stream water, using an elemental analyzer (EA) coupled to an isotope ratio mass spectrometer (IRMS), is described. Stream water samples were concentrated by rotary evaporation, acidified to remove dissolved inorganic carbon (DIC), and dried in silver cups prior to analysis. Precision was evaluated...

متن کامل

A robust and fast method of sampling and analysis of delta13C of dissolved inorganic carbon in ground waters.

The stable carbon isotopic composition of dissolved inorganic carbon (delta13C(DIC)) is traditionally determined using either direct precipitation or gas evolution methods in conjunction with offline gas preparation and measurement in a dual-inlet isotope ratio mass spectrometer. A gas evolution method based on continuous-flow technology is described here, which is easy to use and robust. Water...

متن کامل

Two distinct plant respiratory physiotypes might exist which correspond to fast-growing and slow-growing species.

The origin of the carbon atoms in CO2 respired by leaves in the dark of several plant species has been studied using 13C/12C stable isotopes. This study was conducted using an open gas exchange system for isotope labeling that was coupled to an elemental analyzer and further linked to an isotope ratio mass spectrometer (EA-IRMS) or coupled to a gas chromatography-combustion-isotope ratio mass s...

متن کامل

On-line Quantitative Determination of 2H/1H Isotope Ratios in Organic and Water Samples Using an Elemental Analyser Coupled to an Isotope Ratio Mass Spectrometer

A rapid continuous-Ñow technique for the quantitative determination of hydrogen isotope ratios in organic materials and water, at natural abundance levels, is described. Samples are pyrolysed in a helium stream at 1080 ÄC over an inert form of carbon. Hydrogen is separated from the other pyrolysis gases by gas chromatography and enters the ion source of the isotope ratio mass spectrometer (IRMS...

متن کامل

Liquid chromatography/mass spectrometry stable isotope analysis of dissolved organic carbon in stream and soil waters.

A commercial interface coupling liquid chromatography (LC) to a continuous-flow isotope ratio mass spectrometry (CF-IRMS) instrument was used to determine the δ(13) C of dissolved organic carbon (DOC) in natural waters. Stream and soil waters from a farmland plot in a hedgerow landscape were studied. Based on wet chemical oxidation of dissolved organics the LC/IRMS interface allows the on-line ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 23 12  شماره 

صفحات  -

تاریخ انتشار 2007