Novel 3D computer-automated threshold Amsler grid visual field testing of scotomas in patients with glaucoma.
نویسندگان
چکیده
PURPOSE Three-dimensional (3D) computer-automated threshold Amsler grid testing was used to identify and characterize scotomas typical of glaucoma. METHODS The 3D test exhibits a grid on a computer screen at a preselected grayscale and angular resolution, and allows patients to trace those areas on the grid that are missing in their visual field using a touch screen. Eleven eyes in patients with an established diagnosis of glaucoma were examined according to the above protocol. A total of 23 eyes from normal subjects were used as controls. The 5-minute test required that patients repeatedly outline scotomas on a touch screen with varied displays of contrast while maintaining their gaze on a central fixation marker. A 3D depiction of the visual field defects was then obtained that was further characterized by the location, shape, extent, depth, and slope of the scotomas. RESULTS In this pilot study, the 3D depiction of visual field loss demonstrated paracentral, superior and inferior altitudinal, and nasal step defects consistent with glaucomatous damage. The 3D depiction showed a shape, extent, depth, and slope that are consistent with the severity of damage. CONCLUSIONS The 3D test identified and characterized scotomas typical of glaucoma. The test provides several advantages over conventional perimetry including additional information through 3D depiction of scotomas with the addition of contrast sensitivity and a higher angular/spatial resolution. Improved patient compliance and reliability through shorter testing time and potential interactive accessibility and distribution over the Internet further characterize the test.
منابع مشابه
Novel 3 D Computerized Threshold Amsler Grid Test
Purpose: To introduce a novel 3D computerized threshold Amsler grid test, developed by Fink and Sadun, that allows for a novel characterization of the structure of visual field defects in three dimensions (see http://www.wfbabcom5.com/wf335.htm). Methods: With one eye covered, patients are placed in front of a computer monitor displaying an Amsler grid. While focusing on a varying central fixat...
متن کاملThree-dimensional computer-automated threshold Amsler grid test.
We describe a novel method for testing a visual field that employs a computer monitor with displays of varying contrast that permits unprecedented resolution and characterization of the structure of scotomas in three dimensions. Patients are placed in front of a touch-sensitive computer screen at a fixed distance. With one eye covered, they focus on a central fixation marker and trace with thei...
متن کاملScotomas of age-related macular degeneration detected and characterized by means of a novel three-dimensional computer-automated visual field test.
PURPOSE We used the recently devised three-dimensional computer-based threshold Amsler grid test to acquire and identify typical patterns of visual field defects (scotomas) caused by age-related macular degeneration (AMD). METHODS Patients with AMD traced on a computer touch screen the borders of those areas on an Amsler grid that were missing from their field of vision. Scotomas were repeate...
متن کاملComprehensive Visual Field Test and Diagnosis System for Visual Performance Assessment in Military Settings
We have developed an Internet-based, integrated, and comprehensive visual field test and diagnosis system to assess the visual performance of warfighters, veterans, and civilians. The system is based on the 3D Computerautomated Threshold Amsler Grid (3D-CTAG) test. In multiple clinical studies 3D-CTAG has proven to be innovative and successful for fast, easy, accurate, noninvasive, and comprehe...
متن کاملThreshold Amsler grid as a screening tool for asymptomatic patients on hydroxychloroquine therapy.
BACKGROUND/AIMS Patients taking hydroxychloroquine (HCQ) are at risk of developing classic bull's eye maculopathy. Currently, the standard Amsler grid (AG) is one of the most useful methods to identify such lesions. However, AG is a suprathreshold target and may not detect relative central scotomas. The aim of this study was to determine if the threshold Amsler grid (TAG) test, which varies lig...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of ophthalmology
دوره 19 5 شماره
صفحات -
تاریخ انتشار 2009