Spectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging.

نویسندگان

  • Teresa C Chen
  • Barry Cense
  • Mark C Pierce
  • Nader Nassif
  • B Hyle Park
  • Seok H Yun
  • Brian R White
  • Brett E Bouma
  • Guillermo J Tearney
  • Johannes F de Boer
چکیده

OBJECTIVE To introduce a new ophthalmic optical coherence tomography technology that allows unprecedented simultaneous ultra-high speed and ultra-high resolution. METHODS Using a superluminescent diode source, a clinically viable ultra-high speed, ultra-high resolution spectral domain optical coherence tomography system was developed. RESULTS In vivo images of the retina, the optic nerve head, and retinal blood flow were obtained at an ultra-high speed of 34.1 microseconds (ms) per A-scan, which is 73 times faster than commercially available optical coherence tomography instruments. Single images (B-scans) consisting of 1000 A-scans were acquired in 34.1 ms, allowing video rate imaging at 29 frames per second with an axial resolution of 6 mum. Using a different source in a slightly slower configuration, single images consisting of 500 A-scans were acquired in 34 ms, allowing imaging at 29 frames per second at an axial resolution of 3.5 microm, which is 3 times better than commercially available optical coherence tomography instruments. The amount of energy directed into the eye in both cases, 600 microW, is less than that of the Stratus OCT3 and is safe for intrabeam viewing for up to 8 hours at the same retinal location. CONCLUSION Spectral domain optical coherence tomography technology enables ophthalmic imaging with unprecedented simultaneous ultra-high speed and ultra-high resolution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Macular Edema after Gabapentin

1. Ashworth JL, Biswas S, Wraith E, Lloyd IC. Mucopolysaccharidoses and the eye. Surv Ophthalmol 2006;51:1-17. 2. McDonnell JM, Green WR, Maumenee IH. Ocular histopathology of systemic mucopolysaccharidosis, type II-A (Hunter syndrome, severe). Ophthalmology 1985;92:1772-9. 3. Yoon MK, Chen RW, Hedges TR 3rd, et al. High-speed, ultrahigh resolution optical coherence tomography of the retina in ...

متن کامل

Ultra-high speed and ultra-high resolution spectral-domain optical coherence tomography and optical Doppler tomography in ophthalmology.

We present ultra-high resolution optical coherence tomography (OCT) structural intensity and optical Doppler tomography (ODT) flow velocity images of the human retina in vivo. The ultra-high speed OCT system is based on Spectral Domain or Fourier Domain technology, which provides a sensitivity advantage over conventional OCT of more than 2 orders of magnitude. This sensitivity improvement allow...

متن کامل

Retinal structure of birds of prey revealed by ultra-high resolution spectral-domain optical coherence tomography.

PURPOSE To reveal three-dimensional (3-D) information about the retinal structures of birds of prey in vivo. METHODS An ultra-high resolution spectral-domain optical coherence tomography (SD-OCT) system was built for in vivo imaging of retinas of birds of prey. The calibrated imaging depth and axial resolution of the system were 3.1 mm and 2.8 μm (in tissue), respectively. 3-D segmentation wa...

متن کامل

Optical coherence tomography imaging of ocular and periocular tumours

Optical coherence tomography (OCT) has become pivotal in the practice of ophthalmology. Similar to other ophthalmic subspecialties, ophthalmic oncology has also incorporated OCT into practice. Anterior segment OCT (AS-OCT), ultra-high resolution OCT (UHR-OCT), spectral domain OCT (SD-OCT) and enhanced depth imaging OCT (EDI-OCT), have all been described to be helpful in the diagnosis, treatment...

متن کامل

Ultra-high resolution and long scan depth optical coherence tomography with full-phase detection for imaging the ocular surface

We used a unique combination of four state-of-the-art technologies to achieve a high performance spectral domain optical coherence tomography system suitable for imaging the entire ocular surface. An ultra-high resolution, extended depth range, full-phase interferometry, and high-speed complementary metal-oxide semiconductor transistor camera detection provided unprecedented performance for the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 123 12  شماره 

صفحات  -

تاریخ انتشار 2005