Design of Cold-Formed Steel Screw Connections with Gypsum Sheathing at Ambient and Elevated Temperatures

نویسندگان

  • Wei Chen
  • Jihong Ye
  • Tao Chen
چکیده

Abstract: Load-bearing cold-formed steel (CFS) walls sheathed with double layers of gypsum plasterboard on both sides have demonstrated good fire resistance and attracted increasing interest for use in mid-rise CFS structures. As the main connection method, screw connections between CFS and gypsum sheathing play an important role in both the structural design and fire resistance of this wall system. However, studies on the mechanical behavior of screw connections with double-layer gypsum sheathing are still limited. In this study, 200 monotonic tests of screw connections with singleor double-layer gypsum sheathing at both ambient and elevated temperatures were conducted. The failure of screw connections with double-layer gypsum sheathing in shear was different from that of single-layer gypsum sheathing connections at ambient temperature, and it could be described as the breaking of the loaded sheathing edge combined with significant screw tilting and the loaded sheathing edge flexing fracture. However, the screw tilting and flexing fracture of the loaded sheathing edge gradually disappear at elevated temperatures. In addition, the influence of the loaded edge distance, double-layer sheathing and elevated temperatures is discussed in detail with clear conclusions. A unified design formula for the shear strength of screw connections with gypsum sheathing is proposed for ambient and elevated temperatures with adequate accuracy. A simplified load–displacement model with the post-peak branch is developed to evaluate the load–displacement response of screw connections with gypsum sheathing at ambient and elevated temperatures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cyclic Behavior of Cold-Formed Steel Stud-to-Sheathing Connections

This series of experiments aims to characterize the cyclic behavior of cold-formed steel (CFS) stud-to-sheathing connections. This connection provides the key energy dissipating behavior in wood sheathed CFS shear walls, and provides bracing to the studs under gravity and out-of-plane loads. A simple testing rig is developed consisting of two CFS lipped channels facing toe-to-toe connected on t...

متن کامل

Experimental Study for Strength Capacity of Cold-Formed Steel Joists Connections with Consideration of Various Bolts Arrangements

With growth the construction technologies, Cold-Formed Steel, CFS, sections are widely used in ordinary steel buildings because of some advantages such as light weight, ease of installation, decrease in cost, and increase in speed of operation. Using the bolted connections for CFS joist is one of the best details for steel structures. The main objective of this study is to conduct an experiment...

متن کامل

Review on Cold-Formed Steel Connections

The concept of cold-formed light steel framing construction has been widespread after understanding its structural characteristics with massive research works over the years. Connection serves as one of the important elements for light steel framing in order to achieve its structural stability. Compared to hot-rolled steel sections, cold-formed steel connections perform dissimilarity due to the...

متن کامل

Bracing Stiffness and Strength in Sheathed Cold-formed Steel Stud Walls

The objective of this paper is to provide the stiffness and strength characteristics for coldformed steel stud walls stabilized by sheathing. The primary stability resistance is provided by translational (lateral) stiffness supplied at the fastener locations to the cold-formed steel studs. This paper separates the source of this translational stiffness into two parts: local and diaphragm. To an...

متن کامل

Mechanical Properties of Gypsum Board at Elevated Temperatures

Gypsum board is a common fire barrier used in house and general building construction. Recently, evaluation of the collapses of the World Trade Center Towers highlighted the potential role and failure of gypsum board in containing the fires and resisting damage. The use of gypsum board as primary fire protection of light-flame wood or steel construction is ubiquitous. Yet knowledge of the commo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016