Comparison of the Axis %CDT TIA and the CDTect method as laboratory tests of alcohol abuse.

نویسندگان

  • K Viitala
  • K Lähdesmäki
  • O Niemelä
چکیده

Carbohydrate-deficient transferrin (CDT) has been suggested as a specific marker of alcohol abuse. We designed this study to compare the conventional CDTect method (Pharmacia & Upjohn) and the new semiautomated Axis %CDT turbidimetric immunoassay (%CDT TIA) for their diagnostic performance to identify problem drinking. The sensitivities of the %CDT TIA and CDTect for correctly classifying heavy drinkers (n = 90) were 29% and 59% with the thresholds currently recommended by the manufacturers, respectively. In the control group (n = 114), which included hospitalized patients with abnormal serum transferrin concentrations, the CDTect assay gave 21 false-positive values (18%), whereas the %CDT TIA showed 100% specificity. With the cutoff limits based on the present healthy control group (mean + 2 SD), the sensitivities of the %CDT TIA and CDTect were 61% and 86%, respectively. For men, the ROC plot area of the CDTect results in comparisons of alcohol abusers and healthy controls was significantly (P < 0.05) higher than that of the %CDT TIA results, whereas for women, there was no significant difference in this respect. The slope and intercept (with 95% confidence intervals) for linear regression between CDTect and %CDT TIA were 0.13 (0.12-0.15) and 1.16 (0.73-1.59), respectively (S(y/x) = 1.51, r = 0.744). CDTect results correlated positively with serum transferrin (r = 0.224, P < 0.001), whereas the %CDT TIA results showed a slight inverse correlation with serum transferrin (r = -0.132, P = 0.07). The data suggest that CDTect is more sensitive than %CDT TIA in detecting drinking problems. However, the %CDT TIA method yields more specificity when analyzing samples from patients with high serum transferrin concentrations.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomarkers of Ethanol Consumption

Although excessive ethanol consumption is a major cause of health problems throughout the Western world, the detection of excessive alcohol consumption by laboratory methods continues to lack sensitivity and specificity. Increasing evidence is currently available to indicate that carbohydrate-deficient transferrin (CDT) is a useful marker for assessing potentially harmful alcohol consumption, b...

متن کامل

Diagnostic characteristics of different carbohydrate-deficient transferrin methods in the detection of problem drinking: effects of liver disease and alcohol consumption.

AIMS Due to methodological heterogeneity, conflicting views have been expressed on the validity of CDT measurements in the detection of alcohol misuse. METHODS We compared the characteristics of the conventional CDTect method and the Axis turbidimetric CDT assays in the assessment of 62 alcoholics, who were either with (n = 33) or without (n = 29) liver disease, as analysed by combined clinic...

متن کامل

Comparison of HPLC and small column (CDTect) methods for disialotransferrin.

BACKGROUND Current methods for determination of carbohydrate-deficient transferrin (CDT) are based on separation of the CDT fraction by ion-exchange chromatography on minicolumns and quantification by immunoassay. Alternatively, the transferrin isoforms can be separated by HPLC anion-exchange chromatography and quantified by absorbance. This method has been reported to improve the validity of C...

متن کامل

Interference of transferrin isoform types with carbohydrate-deficient transferrin quantification in the identification of alcohol abuse.

BACKGROUND Isoforms of transferrin interfere with measurement of carbohydrate-deficient transferrin (CDT) as a marker of heavy alcohol consumption. We evaluated the rate of inaccurate CDT results by immunoassays. METHODS We studied 2360 consecutive sera (1614 individuals) submitted for CDT assay without clinical information as well as samples from 1 patient with a congenital disorder of glyco...

متن کامل

Should we use carbohydrate-deficient transferrin instead of gamma-glutamyltransferase for detecting problem drinkers? A systematic review and metaanalysis.

BACKGROUND Carbohydrate-deficient transferrin (CDT) has been used as a test for excessive alcohol consumption in research, clinical, and medico-legal settings, but there remain conflicting data on its accuracy, with sensitivities ranging from <20% to 100%. We examined evidence of its benefit over a conventional and less expensive test, gamma-glutamyltransferase (GGT), and compared the accuracy ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 44 6 Pt 1  شماره 

صفحات  -

تاریخ انتشار 1998