Computer-assisted Cobb angle measurement from posteroanterior radiographs by a curve fitting method

نویسنده

  • İbrahim YILDIZ
چکیده

Incorrect determination of the top or end vertebrae of a scoliotic curve causes measurement errors when using the Cobb method. Such problems are due to subjectivity. This study was performed to minimize subjectivity by using a curve fitting method. A digitally scanned posteroanterior radiographic image was used for each patient. User-defined midpoints of the curvature, which indicate the midpoints of the vertebrae, were used to fit the polynomial equation. The locations of the top and end vertebrae were calculated using the first derivative of the fitted polynomial equation to obtain the analytical Cobb angle. The interobserver technical error of measurements was calculated as 1.06 degrees with a reliability coefficient of 1.00. The results indicate that 100% of the variations were not related to measurement error. Small angle variations show that subjectivity was minimized.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Semi-Automatic Algorithm for Estimating Cobb Angle

Background: Scoliosis is the most common type of spinal deformity. A universal and standard method for evaluating scoliosis is Cobb angle measurement, but several studies have shown that there is intra- and inter- observer variation in measuring cobb angle manually.Objective: Develop a computer- assisted system to decrease operator-dependent errors in Cobb angle measurement.Methods: The spinal ...

متن کامل

Computer-assisted algorithms improve reliability of King classification and Cobb angle measurement of scoliosis.

STUDY DESIGN Interobserver and intraobserver reliability study of improved method to evaluate radiographs of patients with scoliosis. OBJECTIVE To determine the reliability of a computer-assisted measurement protocol for evaluating Cobb angle and King et al classification. SUMMARY OF BACKGROUND DATA Evaluation of scoliosis radiographs is inherently unreliable because of technical and human ...

متن کامل

Computer-Aided Cobb Measurement Based on Automatic Detection of Vertebral Slopes Using Deep Neural Network

Objective To develop a computer-aided method that reduces the variability of Cobb angle measurement for scoliosis assessment. Methods A deep neural network (DNN) was trained with vertebral patches extracted from spinal model radiographs. The Cobb angle of the spinal curve was calculated automatically from the vertebral slopes predicted by the DNN. Sixty-five in vivo radiographs and 40 model r...

متن کامل

Adult Degenerative Scoliosis: Can Cobb Angle on a Supine Posteroanterior Radiograph Be Used to Predict the Cobb Angle in a Standing Position?

It is necessary to assess coronal Cobb angle in the diagnosis and treatment of patients with adult degenerative scoliosis (ADS). But as most ADS patients are elderly patients who are difficult or unable to stand upright without assistance, it is difficult to obtain standing posteroanterior X-ray radiographs. Whether it is possible to use Cobb angle obtained on a supine posteroanterior X-ray rad...

متن کامل

Reliability and reproducibility analysis of the Cobb angle and assessing sagittal plane by computer-assisted and manual measurement tools

BACKGROUND Although many studies on reliability and reproducibility of measurement have been performed on coronal Cobb angle, few results about reliability and reproducibility are reported on sagittal alignment measurement including the pelvis. We usually use SurgimapSpine software to measure the Cobb angle in our studies; however, there are no reports till date on its reliability and reproduci...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016