INTRODUCTION When the Ilizarov external fixator is used for fracture reduction and deformity correction, the planning for correction of 3-D multiple deformities is difficult due to the lack of information on required joint rotations and translations in order to correct the deformities [1]. In addition, if the rotational axis is not placed exactly with respect to axis of the deformity, the rotation may generate the unwanted translational shift at the fracture site [1, 2]. Hexapod external fixator, which is also known as the Taylor spatial frame, has an advantage to kinematically calculate the necessary translations of the telescopic struts in order to correct any 3-D deformities at the fracture site. The purpose of this study was to perform computer aided pre-operative planning of fracture reduction and deformity correction in tibia with single or double hexapod fixator system and to compare the results with the clinical ones.
منابع مشابه
The silhouette technique: improving post-operative radiographs for planning of correction with a hexapod external fixator
Correction of deformity of a bone through use of a hexapod external fixator requires clear definition of the relationship between the bone and the frame. Achieving adequate orthogonal calibrated radiographs for this aim, with minimum X-ray exposure, can prove a challenge in the radiography suite. We describe a simple technique for obtaining adequate imaging, without the use of additional equipm...
متن کاملThree-dimensional correction of complex leg deformities using a software assisted external fixator.
The Taylor Spatial Frame is a computer assisted hexapod system allowing simultaneous correction of every component of complex limb deformities (leg length discrepancy, angulation, translation and rotation). We report our experience with this system in six patients. The planned correction was achieved in all cases. Minor complications occured in all but one patient without consequences; there we...
متن کاملA case report of plastic deformity of fibula and fracture of tibia
Background: Plastic deformity is a fixed deformity of bones after application of force which is in contrast to elastic deformity, so it remains unchanged. It is a rare condition and is seen more commonly in upper extremity (forearm). Inability to recognize it causes limitation of motion and remaining of angular deformity. It occurs more commonly in children because of flexibility of their bones...
متن کاملMechanical rigidity of the Ortho-SUV frame compared to the Ilizarov frame in the correction of femoral deformity
The Ortho-SUV frame (OSF) is a novel hexapod circular external fixator which draws upon the innovation of the Ilizarov method and the advantages of hexapod construction in the three-dimensional control of bone segments. Stability of fixation is critical to the success or failure of an external circular fixator for fracture or osteotomy healing. In vitro biomechanical modelling study was perform...
متن کاملCorrection of tibia vara with six-axis deformity analysis and the Taylor Spatial Frame.
Operative correction for infantile and adolescent tibia vara has been described using both external and internal fixation. Gradual correction using a circular fixator offers the advantage of accurate coronal, sagittal, and axial plane correction without significant soft tissue dissection. This study evaluated the use of six-axis deformity analysis and the Taylor Spatial Frame (TSF) for the corr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2005