A rare cause of endotracheal tube obstruction: a broken stylet going unnoticed--a case report.
نویسندگان
چکیده
In anesthesia practice, stylet is used as an aid in difficult tracheal (ET) intubation. Disposable plastic covered or plastic bougies are recommended but in developing countries, the metal stylets are still in use. Shearing of part of stylet has been reported in past but all incidents were detected immediately. We report a case of tracheal tube blockade due to a broken stylet tip which initially went unnoticed.
منابع مشابه
A Rare Case of Intestinal Obstruction due to Taenia Saginata
Intestinal obstruction may be duo to various mechanical or functional reasons. Worms, especially Ascaris worms are one of the mechanical reasons of intestinal obstruction. Obstruction due to Taenia saginata is a rare phenomenon. Here we report a case of intestinal obstruction due to Taenia saginata infection in a 30 year-old male patient undergoing laparatomy with the diagnosis of intestinal ob...
متن کاملRepeated Tracheostomy Tube Cuff Rupture Due to Tracheobronchopathia Osteochondroplastica: A Case Report
Introduction: Tracheobronchopathia osteochondroplastica (TPO) is a rare benign disorder of the lower part of the trachea and the upper part of the main bronchi. Case Report: A case of tracheobronchopathia osteochondroplastica (TPO) diagnosed at the time of intubation in an intensive care unit due to difficulty when advancing the endotracheal tube beyond the vocal cords, is reported. A problem...
متن کاملPartial Obstruction of the Endotracheal Tube by the Plastic Coating Sheared from a Stylet.
A preterm with gestational age of 24 weeks was intubated at day of life 16. The intubation was done in a routine manner with the use of a stylet. It took a significant effort from the clinician to pull the stylet out after intubation. After intubation the respiratory status of the neonate deteriorated requiring significantly greater support. When ventilating and oxygenating the infant was getti...
متن کاملA Near Miss: Case Report and Literature Review
We report a 28-week gestation premature infant with rare complication of endotracheal intubation. A piece from the plastic sheath of the stylet was retrieved inside the endotracheal tube after extubation.
متن کاملA Piece of Broken Metal from Intubation Stylet Retained in Tracheobronchial Tree: A Case Report
Intubation stylets are still being used in many medical centers for difficult intubations. Although very rare, it may break inside the trachea during endotracheal intubation despite routine pre-assessments by anesthesiologists and may surprisingly move deep into the tracheobronchial tree. In this case report, we describe a rare complication after stylet or guide-wire intubation in a patient in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Middle East journal of anaesthesiology
دوره 19 4 شماره
صفحات -
تاریخ انتشار 2008