SU-E-T-108: 3D Measurement of Neutron Dose from a Novel Neutron Imaging Technique.
نویسندگان
چکیده
PURPOSE We have been developing a fast-neutron spectroscopic technique to quantitatively image the distribution of elements in the body using quasi-monochromatic neutron beams. Previously, we demonstrated the ability of the technique to quantify specific elements in the liver and breast while limiting radiation dose to clinically acceptable levels. Here we present the results of a physical dose measurement performed through neutron irradiation of 3D PRESAGE dosimetry phantoms. METHODS Two PRESAGE optical-CT dosimeters were placed inside a physical phantom of the human torso and irradiated with 8 MeV neutrons produced via the 2H(d,n) reaction using a tandem Van-de-Graaff accelerator. The dosimeters, measuring 10 cm and 4 cm in diameter, were located in regions corresponding to the liver (10 cm), and the kidney (4 cm). Irradiation was performed with the neutron beam incident directly on the larger dosimeter. Cumulative neutron fluence incident upon each dosimeter was determined using an aluminum-foil activation technique. Following irradiation, the change in optical density in both dosimeters was measured to determine the relative irradiation and dose distribution in each volume. RESULTS Both PRESAGE dosimeters exhibited detectable changes in optical density corresponding to the dose deposited in the volume. The two dosimeters registered doses of 8.5 Gy (direct incidence, 4.5 hour irradiation) and 0.25 Gy (off-axis, 20 hour irradiation), respectively. The larger dosimeter showed highest intensity at the entry point of the beam with exponential drop-off along the beam direction. The smaller dosimeter registered a more uniform change in intensity, consistent with the higher incidence of scattered neutrons at this location. CONCLUSION The results demonstrate the utility of PRESAGE dosimeters in measuring dose from neutron irradiation and highlight the difference in relative doses between primary and proximal organs when exposed to neutron beams. This work was supported by the United States Department of Energy, Office of Nuclear Physics under Grant No. DE-FG02-97ER41033, the National Cancer Institute under grant R01CA100835, and by the Department of Defense under award W81XWH-09-1-0066.
منابع مشابه
Estimation of neutron and gamma dose in the MNSR research reactor
In this study, the neutron and gamma doses in the dry channel and in the internal irradiation site of the Miniature Neutron Source research reactor (MNSR) has been calculated and measured. The MNSR reactor is a light water reactor with a maximum power of 30 kW and equipped with various irradiation facilities, including five irradiated sites, five irradiation sites and a dry channel. The interna...
متن کاملA Novel Neutron Dosimeter
Background: Neutron contamination in our environment can cause harmful biological effects on human body. Therefore, many efforts have been made to construct a neutron dosimeter to estimate the received dose. Objective: To design a simple neutron dosimeter. Methods: The primary dosimeter had 3He as a spherical thermal neutron detector encircled by paraffin 10 cm in radius. Then, the paraffin sph...
متن کاملThe Effect of Field Size and Distance from the Field Center on Neutron Contamination in Medical Linear Accelerator
Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many param...
متن کاملThe Effect of Field Size and Distance from the Field Center on Neutron Contamination in Medical Linear Accelerator
Objective: Using Megavoltage photons generated by medical linear accelerator is a common modality for the treatment of malignant. The crucial problem for using photon beams >8MV is the photoneutron yields that increase the risk of secondary cancer that treated with high-energy photon beams. The contaminated neutrons produced in different components of the accelerator head and rely on many param...
متن کاملThe influence of neutron contamination on pacemaker in photon beam radiotherapy by LINAC using the Monte Carlo method
Introduction: In radiation therapy with high-energy photon beams (E > 7 MeV) neutrons are generated mainly in LINACs head thorough (γ, n) interactions. These neutrons affect the shielding requirements in radiation therapy rooms. According to the protocol TG-34, photon absorbed dose of 10Gy can cause permanent damage to the pacemaker and the dose of 2Gy can make minor changes in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 39 6Part11 شماره
صفحات -
تاریخ انتشار 2012