Combination of thermal and cavitation effects to generate deep lesions with an endocavitary applicator using a plane transducer: ex vivo studies.

نویسندگان

  • David Melodelima
  • Jean Yves Chapelon
  • Yves Theillère
  • Dominique Cathignol
چکیده

In the high-intensity focused ultrasound (US), or HIFU, field, it is well-known that the cavitation effect can be used to induce lesions of larger volume. The principle is based on the increase in the equivalent attenuation coefficient of the tissue in the presence of the bubbles created by cavitation. The elementary lesions produced by combination of cavitation and thermal effects, using focused transducers, were spherical and developed upstream of the focal point. This paper presents a method that combines cavitation with a thermal effect to obtain deeper lesions using a plane transducer, rather than a focused one. The cavitation effect was produced by delivering intensities of 60 W/cm2 at the face of the transducer for 0.5 s. The applicator was then rotated through 90 degrees at a constant speed of between 0.5 and 1.5 degrees /s. During this rotation, ex vivo tissues were exposed continuously to an acoustic intensity of 14 W/cm2 to combine the cavitation effect with a thermal effect. The necroses were, on average, twice as deep when the cavitation effect was used as those obtained with a thermal effect alone. Observed macroscopically, the lesions have a very well-delimited geometry. Temperature measurements made at different angles of treatment have shown that they were coagulation necroses.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

64-element intraluminal ultrasound cylindrical phased array for transesophageal thermal ablation under fast MR temperature mapping: an ex vivo study.

This work was undertaken to investigate the feasibility of using a cylindrical phased array for transoesophaeal thermal ablation under magnetic resonance (MR) imaging guidance. Sixty-four transducers (0.45 mm wide by 15 mm tall), operating at 4.6 MHz, were spread around the periphery of a 10.6-mm-diam cylinder. The head of the applicator was covered with a 65-microm thick latex balloon attached...

متن کامل

Transoesophageal ultrasound applicator for sector-based thermal ablation: first in vivo experiments.

New curative and palliative treatments must be proposed to respond to the bad long-term prognosis of oesophageal cancers. It has been demonstrated that high intensity ultrasound (US) can induce rapid, complete and well-defined coagulation necrosis. For the treatment of this cancer, we designed an applicator that uses an intraductal approach. The active part is an air-backed plane transducer. It...

متن کامل

Effect of applicator diameter on lesion size from high temperature interstitial ultrasound thermal therapy.

High temperature ultrasound thermal therapy using interstitial and external approaches is becoming increasingly acceptable as a minimally invasive clinical treatment for cancerous and benign disease. The diameter of an interstitial applicator can influence its clinical practicality and effectiveness as well as application site. The purpose of this study was to determine whether the use of large...

متن کامل

Proceedings of Meetings on Acoustics

Thermal ablation by High Intensity Focused Ultrasound (HIFU) is the only technique for noninvasive treatment of tumours, but suffers from a long treatment times and varied treatment outcomes. Knowledge of the nonlinear parameter B/A can resolve these by improving treatment planning, and correlation between enhanced nonlinear signals and the presence of HIFU lesions has the potential to monitor ...

متن کامل

Detection and exploitation of acoustic cavitation for enhancement of MR guided High Intensity Focused Ultrasound heating in ex vivo liver

Purpose/Introduction High Intensity Focused Ultrasound (HIFU) is increasingly used for the non invasive treatment of pathological tissue. The efficiency of heating can be increased by generation of acoustic cavitation in order to modify the local distribution of ultrasound pressure that can be visualized with Magnetic Resonance Acoustic Force Imaging (MR-ARFI). This studies analyzes the change ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 30 1  شماره 

صفحات  -

تاریخ انتشار 2004