Determination of thiobarbituric acid adduct of malondialdehyde using on-line microdialysis coupled with high-performance liquid chromatography.

نویسندگان

  • Jenn-Yuan Sheu
  • Hsiao-Pei Ku
  • Wei-Chang Tseng
  • Min-Tzu Chen
  • Li-Yu Tsai
  • Yeou-Lih Huang
چکیده

An on-line analytical system for the continuous monitoring of malondialdehyde (MDA) was developed. This method involves the use of microdialysis perfusion, on-line derivatization and on-line HPLC analysis. This method gave a linear response for MDA concentrations and HPLC peak areas in the range from 0.051 microM to 2.43 microM. The intra-day (RSD = 1.6-10.5%) and inter-day (RSD = 1.1-9.3%) precisions were acceptable. The average in vitro probe recovery of MDA standard was 18.4 +/- 1.0%. The detection limit was 0.03 microM, corresponding to 0.6 pmol for an injection volume of 20 microl. This method was used for in vitro peroxidation investigations, which provided evidence for elevated MDA levels following the incubation of metal ions to a linoleic acid solution.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of 5-Hydroxymethyl-2-furaldehyde of Crude and Processed Fructus Corni in Freely Moving Rats Using In Vivo Microdialysis Sampling and Liquid Chromatography

      The purpose of this study was to develop a sensitive and fast microdialysis coupled with high-performance liquid chromatographic (HPLC) method for determination of 5-hydroxymethyl-2-furaldehyde (5-HMF) in free-moving rats after i.g. administration of the aqueous extract of crud Fructus corni and its processed products of jiuzheng pin (JZP). The concentration of 5-HMF in free-movi...

متن کامل

Lipid Peroxidation Process in Meat and Meat Products: A Comparison Study of Malondialdehyde Determination between Modified 2-Thiobarbituric Acid Spectrophotometric Method and Reverse-Phase High-Performance Liquid Chromatography.

The aim of this work was to compare the methods of malondialdehyde detection, as the main secondary product of the lipid peroxidation process, in meat and meat products. Malondialdehyde measurements were performed by two modified methods, the 2-thiobarbituric acid spectrophotometric method and the reverse-phase high-performance liquid chromatography in raw, mechanically-deboned chicken meat and...

متن کامل

Membrane sampling with microdialysis coupled to HPLC/UV for on-line simultaneous determination of melamine and cyanuric acid in non-dairy coffee creamer.

An on-line microdialysis/high-performance liquid chromatography method was developed for the simultaneous determination of melamine and cyanuric acid in non-dairy coffee creamer. To collect these analytes from aqueous samples, the microdialysis system featured a microdialysis probe incorporating a polyarylethersulfone membrane and employed 0.05 M HCl in 0.1% (v/v) MeOH as the perfusate, with o...

متن کامل

Lighter than Water Dispersive Liquid-liquid Microextraction Coupled with High Performance Liquid Chromatography for Determination of Cholecalciferol and Calcifediol from Plasma

In this study, a dispersive liquid–liquid microextraction method using an extraction solvent lighter than water has been developed for the extraction and preconcentration of cholecalciferol and calcifediol from plasma samples followed by high performance liquid chromatography determination. Initially, acetonitrile and sodium chloride (NaCl) are added into the plasma as an extraction solvent and...

متن کامل

Cerebrospinal fluid lipoperoxides quantified by liquid chromatography, and determination of reference values.

Cerebrospinal fluid lipoperoxides, measured as the malondialdehyde-thiobarbituric acid (MDA-TBA) adduct, were quantified by adapting the plasma liquid-chromatographic method of Wong et al. (Clin Chem 1987;33:214-20) to cerebrospinal fluid. Reference values for spinal fluid specimens from 91 adults, ages 17 to 95 y, and 37 children, ages 8 d to 8 y, were determined. Their concentrations were not...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 2003