The use of mutual information in registration of CT and MRI datasets post permanent implant.

نویسندگان

  • Patrick W McLaughlin
  • Vrinda Narayana
  • Marc Kessler
  • Daniel McShan
  • Sara Troyer
  • Lon Marsh
  • George Hixson
  • Peter L Roberson
چکیده

PURPOSE To determine the feasibility of registration of MRI and CT datasets post permanent prostate implant by the use of mutual information. METHODS AND MATERIALS Five patients who underwent permanent (125)I implant for prostate carcinoma were studied. Two weeks postimplant an axial CT, T2-weighted-axial, sagittal and coronal MRI, and T1-fat-saturation MRI scans were obtained. Registrations of MRI to CT and MRI to MRI datasets were performed by mutual information, an automated process of data registration matching all information in specified dataset regions of interest. Registration quality was evaluated by visual inspection, agreement with seed- to-seed registration, and histogram analysis. RESULTS Rapid registration (<30 minutes) of CT and MRI datasets can be accomplished through the use of mutual information. All methods of registration evaluation confirmed excellent registration quality. Although D90 and V100 for the prostate were comparable between MRI- and CT-based dosimetry, dose to critical structures/microenvironments (anterior base, posterior base, bladder outlet, lower sphincter, bulbar urethra) defined on MRI varied widely. CONCLUSIONS Efficient and accurate registration of MRI and CT datasets following prostate implant is possible, and improves the accuracy of postimplant dosimetry by superior definition of the prostate. Definition of critical microenvironments and adjacent structures will improve dose and toxicity correlation and ultimately improve planning strategies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Novel Subsampling Method for 3D Multimodality Medical Image Registration Based on Mutual Information

Mutual information (MI) is a widely used similarity metric for multimodality image registration. However, it involves an extremely high computational time especially when it is applied to volume images. Moreover, its robustness is affected by existence of local maxima. The multi-resolution pyramid approaches have been proposed to speed up the registration process and increase the accuracy of th...

متن کامل

Post‐implant computed tomography–magnetic resonance prostate image registration using feature line parallelization and normalized mutual information

Post-implant dosimetry for permanent prostate brachytherapy is typically performed using computed tomography (CT) images, for which the clear visualization of soft tissue structures is problematic. Registration of CT and magnetic resonance (MR) image volumes can improve the definition of all structures of interest (soft tissues, bones, and seeds) in the joint image set. In the present paper, we...

متن کامل

New Pseudo-CT Generation Approach from Magnetic Resonance Imaging using a Local Texture Descriptor

Background: One of the challenges of PET/MRI combined systems is to derive an attenuation map to correct the PET image. For that, the pseudo-CT image could be used to correct the attenuation. Until now, most existing scientific researches construct this pseudo-CT image using the registration techniques. However, these techniques suffer from the local minima of the non-rigid deformation energy f...

متن کامل

Pseudo-CT Generation from Magnetic Resonance Imaging by fuzzy look up table algorithm

Introduction: Despite growing interest in the use of magnetic resonance imaging (MRI) in the external radiotherapy design process (RT), Computer Tomography (CT) remains a gold standard and is regarded as a basic imaging modality in radiotherapy. MRI shows the high contrast in soft tissues without any radiation exposure to patients. As a result, MRI is used in functional tissue ...

متن کامل

Diagnostic value of CT and MRI of Temporal Bone in Cochlear Implantation Candidates

Background Cochlear implantation is an approved treatment which can be used to treat severe to profound hearing loss. Imaging before cochlear implant surgery is very important in decision making and assessing the temporal bone anatomy for surgery. We aimed to assess the diagnostic value of high resolution CT scan (HRCT), and MRI of temporal bone in candidate pati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brachytherapy

دوره 3 2  شماره 

صفحات  -

تاریخ انتشار 2004