Mechanical failure of the Coonrad-Morrey linked total elbow arthroplasty: A case report.

نویسندگان

  • T T Pham
  • N Bonnevialle
  • M Rongières
  • P Bonnevialle
  • P Mansat
چکیده

Semiconstrained (linked design) total elbow arthroplasty is indicated in a wide variety of cases. Long-term survival is better than with non-linked prostheses. However, mechanical failure of the hinge mechanism is a complication that may occur during follow-up. We report a case of failure of the axle assembly of a Coonrad-Morrey elbow prosthesis 8 years after implantation for nonunion of a supracondylar distal humerus fracture. Initial revision surgery included changing the axle and the polyethylene bushings. Revision surgery was necessary 1 year later when the axle failed again. A custom-designed locking axle had to be used to stabilize the hinge mechanism. After 3 years follow-up, the hinge was intact, there was no loosening of the components and function of the elbow was good.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Revision of failed total elbow arthroplasty with use of a linked implant.

We studied retrospectively the results of revision arthroplasty of the elbow using a linked Coonrad-Morrey implant in 23 patients (24 elbows) after a mean follow-up period of 55 months. According to the Mayo Elbow Performance Score, 19 elbows were satisfactory, nine were excellent and ten good. The median total score had improved from 35 points (20 to 75) before the primary arthroplasty to 85 p...

متن کامل

Total elbow arthroplasty with the Coonrad/Coonrad-Morrey prosthesis. A 10- to 31-year survival analysis.

There have been few reports in the literature of total elbow arthroplasty extending beyond 10 to 15 years. We reviewed 40 patients (41 elbows) with a mean age of 56 years (19 to 83) who had undergone a Coonrad/Coonrad-Morrey elbow arthroplasty by one surgeon for various diagnoses between 1974 and 1994. Surgical selection excluded patients with previous elbow infection or who refused to accept a...

متن کامل

Coonrad-Morrey total elbow arthroplasty for tumours of the distal humerus and elbow.

We reviewed 20 patients who had undergone a Coonrad-Morrey total elbow arthroplasty after resection of a primary or metastatic tumour from the elbow or distal humerus between 1980 and 2002. Eighteen patients underwent reconstruction for palliative treatment with restoration of function after intralesional surgery and two after excision of a primary bone tumour. The mean follow-up was 30 months ...

متن کامل

Is Coonrad-Morrey total elbow arthroplasty a viable option for treatment of distal humeral nonunions in the elderly?

OBJECTIVE The purpose of this study was to evaluate the functional and radiological results of semiconstrained Coonrad-Morrey total elbow arthroplasty for distal humeral nonunions in the mid-term period. METHODS Seven patients were treated with Coonrad-Morrey total elbow arthroplasty for distal humeral nonunion. All patients were female, and the mean age was 65.6 years (range: 64-68 years). P...

متن کامل

Fatigue Strength Evaluation of Total Elbow Prostheses Humeral and Ulnar Stems

Introduction: Isolated stem fractures have been reported for total elbow replacements (TER) and are most frequently associated with 1) younger patients with high activity levels and 2) poor boney support conditions associated with post-traumatic arthritis [1-4]. No international test standards exist to evaluate fatigue strength of humeral and ulnar stems of a TER. Therefore, a test method was d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Orthopaedics & traumatology, surgery & research : OTSR

دوره 100 7  شماره 

صفحات  -

تاریخ انتشار 2014