Erratum to: Post renal biopsy complication rate and diagnostic yield comparing hands free (ultrasound-assisted) and ultrasound-guided biopsy techniques of renal allografts and native kidneys

نویسندگان

  • Hatem Ali
  • Asam Murtaza
  • John Anderton
  • Aimun Ahmed
چکیده

BACKGROUND Real time ultrasound guided percutaneous kidney biopsy has become the standard procedure to assess the pathology of native kidneys and renal transplants. No specific technique has shown to be totally free of post biopsy bleeding complications. Few Studies have looked at the rates of post biopsy bleeding complications comparing different needle size, post biopsy haematoma size, or clinical predictors of the complication rates. In this study we aim to assess safety and adequacy of the real time ultrasound guided biopsy using free hands (ultrasound-assisted) and ultrasound-guided technique. METHOD The results of 527 elective native and kidney transplant biopsy performed as a day case procedure at Lancashire Teaching Hospitals were retrospectively reviewed (499 native and 28 allograft biopsies). Biopsies were grouped into 4 groups according to the technique and the needle size; group 1 (n = 119; performed by free hands-ultrasound assisted- technique using 14G needle) Group 2 (n = 59; performed by free hands-ultrasound-assisted technique using 16G needle), group 3 (n = 195; performed by ultrasound-guided technique using 14G), and group 4 (n = 154; performed by ultrasound-guided technique using 16G). The 4 groups were matched in age, sex, weight, haemoglobin, serum creatinine, INR, PT, and PTT time. RESULTS The overall tissue specimen was adequate in 80.45 % of the cases, with no difference between group 1 and 3 (81.5 and 80.52 % respectively, p = 0.82) or between group 2 and 4 (86.44 and 77.3 % respectively, p = 0.13). The overall major complications rate was 2.84 %, with no difference between group 1 and 3 (2.5 and 1 % respectively, p = 0.30) or group 2 and 4 (5 and 4.5 % respectively, p = 0.86). The overall minor complications was 3.7 % with no difference between group 2 and 4 (3.3 and 5.84 % respectively, p = 0.46), however, minor complications were higher in group 1 compared to group 3 (5.8 and 1 % respectively, p = 0.01).There was no difference between using 14G and 16G needle size in terms of tissue adequacy(p = 0.7), major complications (p = 0.2 for drop in Hb >10 g/l, p = 0.08 for blood transfusion, p = 0.35 for embolization) or minor complication items(p = 0.4 for drop in Hb, 10 g/l,p = 0.1 for haematuria, p = 0.7 for hematoma). CONCLUSION When using a 14G needle, there is higher risk of minor complications in the free hands-(ultrasound-assisted) technique compared to the ultrasound-guided technique. There is no difference in the rates of major or minor complications between free hand and needle-guided technique using 16G needles. Both techniques showed adequate tissue sampling.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Post renal biopsy complication rate and diagnostic yield comparing hands free (ultrasound-assisted) and ultrasound-guided biopsy techniques of renal allografts and native kidneys

Background: Real time ultrasound guided percutaneous kidney biopsy has become the standard procedure to assess the pathology of native kidneys and renal transplants. No specific technique has shown to be totally free of post biopsy bleeding complications. Few Studies have looked at the rates of post biopsy bleeding complications comparing different needle size, post biopsy haematoma size, or cl...

متن کامل

Radial Probe Endobronchial Ultrasound for Peripheral Pulmonary Lesions: Initial Experience in an Indian Tertiary Healthcare Centre

Introduction : Diagnosis of peripheral pulmonary nodules is confusing; therefore, an accurate and safe lung biopsy can prevent unnecessary invasive diagnostic procedures. This study soughtto study the diagnostic yield, sensitivity, specificity, and negative and positive predictive values (NPV and PPV) of radial probe endobronchial ultrasound (EBUS)-guided biopsy for peripheral pulmonary lesions...

متن کامل

Safety and tissue yield for percutaneous native kidney biopsy according to practitioner and ultrasound technique

BACKGROUND Although percutaneous renal biopsy remains an essential tool in the diagnosis and treatment of renal diseases, in recent times the traditional procedure of nephrologists has been performed by non-nephrologists rather than nephrologists at many institutions. The present study assessed the safety and adequacy of tissue yield during percutaneous renal biopsy according to practitioners a...

متن کامل

Ultrasound-Guided Percutaneous Renal Biopsy in 295 Children and Adolescents: Role of Ultrasound and Analysis of Complications

INTRODUCTION Percutaneous renal biopsy (PRB) is a decisive diagnostic procedure for children and adolescents with renal diseases. Aim of this study was to evaluate retrospectively the complication rates of percutaneous kidney biopsies and their therapeutic consequences to assess the role of ultrasound-guidance including Doppler ultrasound examinations in preparation, execution and follow-up car...

متن کامل

Renal biopsy with 16G needle: a safety study.

INTRODUCTION AND OBJECTIVE The development of percutaneous renal biopsy as a routinary diagnostic procedure for renal masses is topic of discussion for the last few years. However, this technique has been associated with some complications, although infrequent, and morbidity. Our objective is to carry out a descriptive study about complications and outcomes of orthotopic kidney biopsies with 16...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2015