Electron Beam, 3.5mv, 2ka Injector Diode Diagnostics for the Darht Facility*

نویسنده

  • S. Eylon
چکیده

The injector for the second axis of the dual-axis Radiographic Hydrotest Facility (DARRT) is being designed and manufactured in LBNL. The injector consists of a single gap diode, extracting at 2 microseconds, 2kA (can be extended to 4kA), up to 3.5MV electrons from a dispenser cathode. The diode is powered through a high voltage insulating column by a Marx generator. We shall present an overview of the 3.5MV diode diagnostics, including: the A-K gap voltage measurement using a capacitive voltage divider (dE/dt) probe’, cathode (source) current using 12 low inductance stainless steel foil current viewing resistors (CVRs) located on the cathode base plate’, and anode dark current collected on the anode shroud using CVRs. A rise in the dark current, can indicate a buildup of an A-K breakdown, and is used to trigger the injector crowbar switch, thus limiting breakdown damage. Beam spillage, generating X-rays around the anode tube and shroud, is monitored using solid state PIN diodes positioned around the anode tube. Furthermore, we shall present the diode diagnostic system conceptual design, development tests, manufacturing and the results of some acceptance tests.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Time Dependent Beam Focusing at the Darht-ii Injector Diode

The injector for the second axis of the Dual-Axis Radiographic Hydrotest Facility (DARHT) is being designed and constructed at LBNL. The injector consists of a single gap diode extracting 2μ s, 2kA,3.2 MeV electron beam from a 6.5 inches diameter thermionic dispenser cathode. The injector is powered through a ceramic column by a Marx generator. We also investigated the possibility of extracting...

متن کامل

High Voltage, High Current, Long Pulse Electron Beam Injector for Darht

An injector design for the long pulse option for the second axis of the Dual-Axis Radiographic Hydrotest Facility (DARHT) has been studied. This design is based on the LBNL Heavy Ion Fusion Injector technology. The proposed injector consists of a single gap diode extracting electrons from a thermionic source and powered through a high voltage ceramic insulator column by a Marx generator. The ke...

متن کامل

Diagnostics for a 1.2 kA, 1 MeV, Electron Induction Injector

We are constructing a 1.2 kA, 1 MeV, electron induction injector as part of the RTA program, a collaborative effort between LLNL and LBNL to develop relativistic klystrons for Two-Beam Accelerator applications. The RTA injector will also be used in the development of a high-gradient, low-emittance, electron source and beam diagnostics for the second axis of the Dual Axis Radiographic Hydrodynam...

متن کامل

The Darht-ii Electron Injector

The injector for the second axis of the Dual-Axis Radiographic Hydrotest Facility (DARHT) is being designed and constructed at LBNL. The injector consists of a single gap diode extracting 2 μs, 2 kA, 3.2 MeV electron beam from a 6.5 inches diameter thermionic dispenser cathode. The injector is powered through a ceramic column by a Marx generator. We also investigated the possibility of extracti...

متن کامل

The Darht Phase 2 Linac*

The second phase accelerator for the Dual Axis Hydrodynamic Test facility (DARHT) is designed to provide an electron beam pulse that is 2μs long, 2kA, and 20 MeV in particle energy. The injector provides 3.2 MeV so that the linac need only provide 16.8 MeV. The linac is made with two types of induction accelerator cells. The first block of 8 cells have a 14 in. beam pipe compared to 10 in. in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2000