Methodological parameters influence the detection of right-to-left shunts by contrast transcranial Doppler ultrasonography.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Contrast transcranial Doppler ultrasonography is a new method to detect intracardiac right-to-left shunts, such as the patent foramen ovale. However, the methodology of the procedure varies considerably among investigators. This study was undertaken to assess the influence of methodological parameters on the results of the contrast transcranial Doppler examination in the detection of right-to-left shunts. METHODS A total of 72 patients (mean age, 58.2+/-14.7 years) had a contrast transcranial Doppler ultrasonography examination. To study the influence of methodological factors, patients with evidence of a right-to-left shunt underwent repeated examinations with modified procedures. Parameters under investigation were the timing of the Valsalva maneuver, the dose of the contrast medium, and the patient's posture during the examination. RESULTS The median contrast signal count was 58.5 and 48.0 (P<0.001) and the median latency of the first intracranially detected contrast signal was 12.5 and 8.5 seconds (P=0.05) when the Valsalva maneuver was performed 5 and 0 seconds after the start of the injection, respectively. Reducing the contrast medium dose from 10 to 5, 2.5, and 1.2 mL resulted in a decline of the median signal count from 54.5 to 28.5, 20.5, and 12.0 (P<0.01), respectively, while the latency of the first contrast signal increased from 13.3 to 14.0, 14.6, and 15.0 seconds (P<0.05). The sitting position also produced a lower signal count than the supine position (P<0.02). CONCLUSIONS This study demonstrates that several essential methodological parameters influence the results of the contrast transcranial Doppler ultrasonography examination. Therefore, it is necessary to standardize the procedure to permit comparable quantitative assessments of the shunt volume. The findings of the present study suggest that 10 mL of contrast medium be injected with the patient in the supine position and that the Valsalva maneuver be performed 5 seconds after the start of the injection.
منابع مشابه
Results of Transcranial Doppler in Children with Sickle Cell Disease: Correlation between the Time-Averaged Mean of Maximum Velocity and Some Hematological Characteristics
Abstract Background: Transcranial Doppler ultrasonography results have not been previously studied in among Iranian sickle cell anemia patients. The present study was performed to evaluate the pattern of intracranial flow velocities among Iranian children with sickle cell anemia and the hematological parameters that can affect the time-averaged mean of maximum velocity in major intracranial...
متن کاملContrast transcranial Doppler ultrasound in the detection of right-to-left shunts. Reproducibility, comparison of 2 agents, and distribution of microemboli.
BACKGROUND AND PURPOSE Cardiac right-to-left shunts can be identified by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and by transesophageal echocardiography (TEE). Systematic data are available on neither the reproducibility of contrast TCD, the comparison of different contrast agents, nor the comparison of simultaneous bilateral to unilateral recordings. Fur...
متن کاملContrast Enhanced Echocardiography for Detection of Intrapulmonary Shunts in Liver Transplant Candidates
Background: Intrapulmonary vascular abnormalities associated with liver cirrhosis may result in intrapulmonary right-to-left shunt and hypoxemia. The aim of this study was to use contrast enhanced echocardiography to detect intrapulmonary vascular abnormalities in patients with liver cirrhosis candidates for liver transplantation. Methods: One hundred and two adult patients underwent contrast e...
متن کاملContrast transcranial Doppler ultrasound in the detection of right-to-left shunts: comparison of different procedures and different contrast agents.
BACKGROUND AND PURPOSE Cardiac right-to-left shunts can be identified by transesophageal echocardiography (TEE) and by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and different provocation procedures. Currently, data on an appropriate time window for the appearance of contrast bubbles in the TCD recording after the injection of the contrast medium and the com...
متن کاملContrast Transcranial Doppler Ultrasound in the Detection of Right-to-Left Shunts
Background and Purpose—Cardiac right-to-left shunts can be identified by transcranial Doppler ultrasound (TCD) with the use of different contrast agents and by transesophageal echocardiography (TEE). Systematic data are available on neither the reproducibility of contrast TCD, the comparison of different contrast agents, nor the comparison of simultaneous bilateral to unilateral recordings. Fur...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 30 6 شماره
صفحات -
تاریخ انتشار 1999