Numerical optimization of sequential cryogen spray cooling and laser irradiation for improved therapy of port wine stain.

نویسندگان

  • Matija Milanič
  • Wangcun Jia
  • J Stuart Nelson
  • Boris Majaron
چکیده

BACKGROUND AND OBJECTIVE Despite application of cryogen spray (CS) precooling, customary treatment of port wine stain (PWS) birthmarks with a single laser pulse does not result in complete lesion blanching for a majority of patients. One obvious reason is nonselective absorption by epidermal melanin, which limits the maximal safe radiant exposure. Another possible reason for treatment failure is screening of laser light within large PWS vessels, which prevents uniform heating of the entire vessel lumen. Our aim is to identify the parameters of sequential CS cooling and laser irradiation that will allow optimal photocoagulation of various PWS blood vessels with minimal risk of epidermal thermal damage. STUDY DESIGN AND METHODS Light and heat transport in laser treatment of PWS are simulated using a custom 3D Monte Carlo model and 2D finite element method, respectively. Protein denaturation in blood and skin are calculated using the Arrhenius kinetic model with tissue-specific coefficients. Simulated PWS vessels with diameters of 30-150 µm are located at depths of 200-600 µm, and shading by nearby vessels is accounted for according to PWS histology data from the literature. For moderately pigmented and dark skin phototypes, PWS blood vessel coagulation and epidermal thermal damage are assessed for various parameters of sequential CS cooling and 532-nm laser irradiation, i.e. the number of pulses in a sequence (1-5), repetition rate (7-30 Hz), and radiant exposure. RESULTS Simulations of PWS treatment in darker skin phototypes indicate specific cooling/irradiation sequences that provide significantly higher efficacy and safety as compared to the customary single-pulse approach across a wide range of PWS blood vessel diameters and depths. The optimal sequences involve three to five laser pulses at repetition rates of 10-15 Hz. CONCLUSIONS Application of the identified cooling/irradiation sequences may offer improved therapeutic outcome for patients with resistant PWS, especially in darker skin phototypes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental study of multiple-intermittent cryogen spurts and laser pulses for the treatment of port wine stain birthmarks

Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during pulsed laser treatment of port wine stain (PWS) birthmarks. Unfortunately, the current approach to CSC does not provide the necessary epidermal protection for all patients, particularly those with darker skin types. Therefore, alternative approaches need to be sought to improve PWS laser therapy. On a previous n...

متن کامل

Sequential cryogen spraying for heat flux control at the skin surface

Heat transfer rate at the skin-air interface is of critical importance for the benefits of cryogen spray cooling in combination with laser therapy of shallow subsurface skin lesions, such as port -wine stain birthmarks. With some cryogen spray devices, a layer of liquid cryogen builds up on the skin surface during the spurt, which may impair heat transfer across the skin surface due to relative...

متن کامل

Epidermal protection with cryogen spray cooling during high fluence pulsed dye laser irradiation: an ex vivo study.

BACKGROUND AND OBJECTIVE Higher laser fluences than currently used in therapy (5-10 J/cm(2)) are expected to result in more effective treatment of port wine stain (PWS) birthmarks. However, higher incident fluences increase the risk of epidermal damage caused by absorption of light by melanin. Cryogen spray cooling offers an effective method to reduce epidermal injury during laser irradiation. ...

متن کامل

Intermittent cryogen spray cooling for optimal heat extraction during dermatologic laser treatment.

Fast heat extraction is critically important to obtain the maximal benefit of cryogen spray cooling (CSC) during laser therapy of shallow skin lesions, such as port wine stain birthmarks. However, a film of liquid cryogen can build up on the skin surface, impairing heat transfer due to the relatively low thermal conductivity and higher temperature of the film as compared to the impinging spray ...

متن کامل

Cryogen spray cooling efficiency: improvement of port wine stain laser therapy through multiple-intermittent cryogen spurts and laser pulses.

BACKGROUND AND OBJECTIVES Cryogen spray cooling (CSC) is used to minimize the risk of epidermal damage during laser treatment of port wine stain (PWS) birthmarks. Unfortunately, CSC may not provide the necessary protection for patients with high concentrations of epidermal melanin. The objectives of this study are to: (1) provide a definition of cooling efficiency (eta) based on the amount of h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lasers in surgery and medicine

دوره 43 2  شماره 

صفحات  -

تاریخ انتشار 2011