Comparison of PACS and hard-copy 51-inch radiographs for measuring leg length and deformity.

نویسندگان

  • Saurabh Khakharia
  • Daniel Bigman
  • Austin T Fragomen
  • Helene Pavlov
  • S Robert Rozbruch
چکیده

BACKGROUND The picture archiving and communication system (PACS) eventually will replace the use of standard hard-copy radiographs. It is unknown whether measurements of limb length discrepancy (LLD) and deformity on PACS compare in accuracy and reproducibility with those from hard-copy radiographs. QUESTIONS/PURPOSES We compared the reproducibility and reliability of LLD and deformity measurements for each of these two media. METHODS We retrospectively reviewed 51-inch standing lower extremity images obtained for LLD or deformity analysis from 40 patients to compare the measurements and their reliability on hard-copy film with those performed on soft-copy PACS. Two observers independently performed measurements twice using each system at 1-week intervals to minimize interobserver or intraobserver bias. Intraclass correlation coefficients (ICCs) were determined to test intraobserver and interrater reliability of Rater 1 and Rater 2. RESULTS Interrater reliability of measurements made on hard copy ranged from 0.69 to 0.99 and PACS-derived measurements ranged from 0.66 to 0.98. Intraobserver reliability for Rater 1 for measurements made on hard copy ranged from 0.853 to 0.999 and PACS-derived measurements ranged from 0.80 to 0.996. Intraobserver reliability for Rater 2 for measurements made on hard copy ranged from 0.931 to 0.999 and PACS-derived measurements ranged from 0.962 to 0.999. CONCLUSIONS Each system yielded comparable reliability for measurements, therefore, transition to PACS to perform measurements in patients with LLD or deformity can be made with confidence. LEVEL OF EVIDENCE Level III, diagnostic study. See the Guidelines for Authors for a complete description of levels of evidence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

  Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...

متن کامل

Comparison of PACS and Bone Ninja mobile application for assessment of lower extremity limb length discrepancy and alignment

PURPOSE There are over 500 medically related applications (apps) for mobile devices. Very few of these applications undergo testing and peer-review for accuracy. The purpose of this study is to assess the accuracy of limb deformity measurements on the Bone Ninja app compared to PACS and to determine the intra- and inter-observer variability among different orthopaedic practitioners. METHODS F...

متن کامل

A case report of plastic deformity of fibula and fracture of tibia

Background: Plastic deformity is a fixed deformity of bones after application of force which is in contrast to elastic deformity, so it remains unchanged. It is a rare condition and is seen more commonly in upper extremity (forearm). Inability to recognize it causes limitation of motion and remaining of angular deformity. It occurs more commonly in children because of flexibility of their bones...

متن کامل

Editorial Board

in the name of God, most gracious, most merciful Physiology and Pharmacology Indexing: Index Copernicus (IC), Scientific Information Database (SID) Physiology and Pharmacology is the official publication of the Iranian Society of Physiology and Pharmacology. The journal publishes full-length original articles in physiology, pharmacology and related subjects. Editorial office: ...

متن کامل

Correlation of cervical sagittal alignment parameters on full-length spine radiographs compared with dedicated cervical radiographs

BACKGROUND Radiographic parameters to evaluate the cervical spine in adult deformity using 36-inch films have been proposed. While 36-inch films are used to evaluate spinal deformity, dedicated cervical films are more commonly used to evaluate cervical spine pathology. The purpose of this study is to determine correlations between sagittal measures from a dedicated cervical spine radiographs an...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical orthopaedics and related research

دوره 469 1  شماره 

صفحات  -

تاریخ انتشار 2011