Doppler coherence imaging and tomography of flows in tokamak plasmas (invited).

نویسندگان

  • J Howard
  • A Diallo
  • M Creese
  • B D Blackwell
  • S L Allen
  • R M Ellis
  • G D Porter
  • W Meyer
  • M E Fenstermacher
  • N H Brooks
  • M E Van Zeeland
  • R L Boivin
چکیده

This article describes the results of spatial heterodyne Doppler "coherence imaging" of carbon ion flows in the divertor region of the DIII-D tokamak. Spatially encoded interferometric projections of doubly ionized carbon emission at 465 nm have been demodulated and tomographically inverted to obtain the spatial distribution of the carbon ion parallel flow and emissivity. The operating principles of the new instruments are described, and the link between measured properties and line integrals of the flow field are established. An iterative simultaneous arithmetic reconstruction procedure is applied to invert the interferometric phase shift projections, and the reconstructed parallel flow field amplitudes are found to be in reasonable agreement with UEDGE modeling.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Coherence imaging of scrape-off-layer and divertor impurity flows in the Mega Amp Spherical Tokamak (invited).

A new coherence imaging Doppler spectroscopy diagnostic has been deployed on the UK's Mega Amp Spherical Tokamak for scrape-off-layer and divertor impurity flow measurements. The system has successfully obtained 2D images of C III, C II, and He II line-of-sight flows, in both the lower divertor and main scrape-off-layer. Flow imaging has been obtained at frame rates up to 1 kHz, with flow resol...

متن کامل

Coherence imaging of scrape-off-layer and divertor impurity flows in the Mega Amp Spherical Tokamak (invited)a)

Publisher's copyright statement: c © 2014 American Institute of Physics. This article may be downloaded for personal use only. Any other use requires prior permission of the author and the American Institute of Physics. The following article appeared in Silburn, S. A., Harrison, J. R., Howard, J., Gibson, K. J., Meyer, H., Michael, C. A. and Sharples, R. M. (2014) 'Coherence imaging of scrape-o...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Enhanced imaging of choroidal vasculature by high-penetration and dual-velocity optical coherence angiography

Dual-beam-scan Doppler optical coherence angiography (DB-OCA) with a 1-μm-wavelength probe is demonstrated for improved in vivo choroidal angiograms of the human eye. This method utilizes two scanning beams with spatial and temporal separation on the retina, and provides two measurable velocity ranges. The method achieves higher sensitivity to very low velocity flows than conventional Doppler o...

متن کامل

New plasma measurements with a multichannel millimeter-wave fluctuation diagnostic system in the DIII-D tokamak

Citation Hillesheim, J. C. et al. " New plasma measurements with a multichannel millimeter-wave fluctuation diagnostic system in the DIII-D tokamak (invited). " Review of Scientific Instruments 81 (2010): 10D907. Article is made available in accordance with the publisher's policy and may be subject to US copyright law. Please refer to the publisher's site for terms of use. The MIT Faculty has m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 81 10  شماره 

صفحات  -

تاریخ انتشار 2010