Information content of SNR/resolution trade-offs in three-dimensional magnetic resonance imaging.
نویسندگان
چکیده
In MRI, a trade-off exists between resolution and signal-to-noise ratio, since different fractions of the available scan time can be used to acquire data at higher spatial frequencies and to perform signal averaging. By comparing a wide variety of 3D isotropic MR scans with different combinations of SNR, resolution, and scan duration, the impact of this trade-off on the image information content was assessed. The information content of mouse brain, mouse whole-body, and human brain images was evaluated using a simple numerical approach, which sums the information contribution of each individual k-space data point. Results show that, with a fixed receiver bandwidth and field of view, the information content of trade-off images is always maximized when the SNR is equal to about 16. The optimal imaging resolution is dependent on the scan duration, as well as certain MR system properties, such as field strength and coil sensitivity. These properties are, however, easily accounted for with the acquisition of a single scout MR image, and the optimal imaging resolution can then be calculated using a simple mathematical relationship. If the imaging task is approached with a predetermined resolution requirement, the same scout scan can be used to calculate the scan duration that will provide the maximum possible information. Using these relationships to maximize the image information content is an excellent technique for guiding the initial selection of imaging parameters.
منابع مشابه
Super-Resolution Reconstruction in MRI: Better Images Faster?
Improving the resolution in magnetic resonance imaging (MRI) is always done at the expense of either the signal-to-noise ratio (SNR) or the acquisition time. This study investigates whether so-called super-resolution reconstruction (SRR) is an advantageous alternative to direct high-resolution (HR) acquisition in terms of the SNR and acquisition time trade-offs. An experimental framework was de...
متن کاملDesigning and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance
Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...
متن کاملAccelerating time-resolved MRA with multiecho acquisition.
A new four-dimensional magnetic resonance angiography (MRA) technique called contrast-enhanced angiography with multiecho and radial k-space is introduced, which accelerates the acquisition using multiecho while maintaining a high spatial resolution and increasing the signal-to-noise ratio (SNR). An acceleration factor of approximately 2 is achieved without parallel imaging or undersampling by ...
متن کاملFabrication of New 3D Phantom for Measuring Geometric Distortion in Magnetic Resonance Imaging System
Introduction: Geometric distortion is a major shortcoming of magnetic resonance imaging (MRI), which has an important influence on the accuracy of volumetric measurements, an important parameter in neurology and oncology. Our goal is to design and construct a new three- dimensional phantom using a 3D printer in order to measure geometric distortion and its reproducibility in...
متن کاملFat/water separation using a concentric rings trajectory.
The concentric rings two-dimensional (2D) k-space trajectory enables flexible trade-offs between image contrast, signal-to-noise ratio (SNR), spatial resolution, and scan time. However, to realize these benefits for in vivo imaging applications, a robust method is desired to deal with fat signal in the acquired data. Multipoint Dixon techniques have been shown to achieve uniform fat suppression...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Medical physics
دوره 36 4 شماره
صفحات -
تاریخ انتشار 2009