3D Printing Model before and after Transcatheter Aortic Valve Implantation for a Better Understanding of the Anatomy of Aortic Root
نویسندگان
چکیده
A 71-year-old woman had severe aortic stenosis (AS) (aortic valve area, 0.6 cm; mean valve gradient, 47 mmHg; and peak velocity, 4.2 m/s) and cardiac symptoms. She had a history of stroke and paroxysmal atrial fibrillation. Our multidisciplinary heart team decided to perform transcatheter aortic valve implantation (TAVI). Before TAVI, computed tomography (CT) was performed, and the measurements of the aortic annulus were as follows: diameter, 25.4x19 mm; perimeter, 71.2 mm; area, 3.72 cm; distance to the right coronary artery, 13.2 mm; and distance to the left coronary artery, 12.3 mm (Fig. 1A). Using the CT data, a 3D printing model was created (Materialise, Luven, Belgium). 3D printing model provided the cardiologist with an intuitive perception of the cardiovascular anatomy and measurements in preparation for TAVI (Fig. 1B and C). A 23-mm Edward-Sapien prosthetic valve (Edwards Lifesciences, Irvine, CA, USA) was selected. TAVI was successfully performed with mild paravalvular leakage of the left coronary sinus (Fig. 1D). A postTAVI 3D model clearly showed the position of the replaced valve (Fig. 1E), change in the aortic annulus (i.e., from an oval to a round shape) (Fig. 1F), and the site of mild paravalvular leakage (Fig. 1G). CT is essential tool for TAVI. Although CT measurements increase the success rate of TAVI, its success is highly dependent on the operator’s skill and expertise. A 3D printing model may offer a greater possibility for simulating patient specific complex structural characterization procedures and overcome the limitation of noninvasive TAVI-poor direct visualization.
منابع مشابه
Computer-aided design of the human aortic root
The development of computer-based 3D models of the aortic root is one of the most important problems in constructing the prostheses for transcatheter aortic valve implantation. In the current study, we analyzed data from 117 patients with and without aortic valve disease and computed tomography data from 20 patients without aortic valvular diseases in order to estimate the average values of the...
متن کاملTranscatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملBicuspid Aortic Valve: An Unusual Cause of Aneurysm of Left Coronary Sinus of Valsalva
Bicuspid aortic valve is traditionally considered an innocuous congenital anomaly. Due to a better and widespread availability of non-invasive imaging techniques, it has come to the fore that 30% of these cases develop complications, viz., valve abnormality (aortic regurgitation and stenosis), and aneurysm of aortic root and ascending aorta. Sinus of Valsalva aneurysm is an uncommon complicatio...
متن کاملSCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR).
Computed tomography (CT) plays an important role in the workup of patients who are candidates for implantation of a catheter-based aortic valve, a procedure referred to as transcatheter aortic valve implantation (TAVI) or transcatheter aortic valve replacement (TAVR). Contrast-enhanced CT imaging provides information on the suitability of the peripheral access vessels to accommodate the relativ...
متن کاملImpact of aortic regurgitation after transcatheter aortic valve implantation: results from the REVIVAL trial.
OBJECTIVES Understanding the severity of aortic regurgitation (AR) after transcatheter aortic valve implantation, its impact on left ventricular (LV) structure and function, and the structural factors associated with worsening AR could lead to improvements in patient selection, implantation technique, and valve design. BACKGROUND Initial studies in patients at high risk of surgical aortic val...
متن کامل