Coronagraphy with HST/NICMOS: detectability is a sensitive issue

نویسندگان

  • Glenn Schneider
  • Murray Silverstone
چکیده

HST provides an unparalleled venue for high contrast imaging which has enabled new observational domains in exoplanet and debris disk imaging. Unburdened by atmospheric "seeing", NICMOS and STIS achieve very low levels of background contamination from the wings of stellar point spread functions (PSF). Coronagraphy provides additional contrast gains approaching an order of magnitude at small angular distances from occulted stars. The stability of the platform allows scattered and diffracted light to be further reduced by two additional orders of magnitude through PSFsubtraction. The non-destructive read-out modes of the NICMOS detectors permit sampling the PSF, with its strong radial brightness gradient, over a dynamic range exceeding 5x107 in a single spacecraft orbit. In H-band, sub-stellar companions of ∆H ≈ 8 + 2 × (angular separation in arcseconds) are unambiguously detected in twenty minutes of integration (e.g., a 10 Myr "hot Jupiter" at 2.5 arcseconds from an occulted star). Raw sensitivity metrics, such as presumtively static Strehl ratios, are often invoked in comparing the performance of different instrumental systems but belie the true detectability levels which are dominated by systemic non-repeatable PSF variations (not photon statistics). Such variations can give rise to false detections of companions (and circumstellar disks) and introduce very significant photometric errors. The ability to rotate the HST field with high precision about the target axis and acquire temporally stable reference PSFs readily permits the identification and rejection of rotationally-invariant optical artifacts. We discuss the repeatable, quantifiable performance limits routinely reached by HST (currently unachievable on groundbased systems), for which PSF stability is critical.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

NICMOS Coronagraphy: Recalibration and the NICMOS Legacy Archive PSF Library

NICMOS coronagraphy, with well-matched template Point Spread Function (PSF) subtraction, probes the closest environments of occulted targets with the highest imaging sensitivity in intrinsically high contrast fields at the smallest radial distances afforded, uniquely, by HST. NICMOS PSF-subtracted coronagraphy has been invoked in a wide variety of HST programs with science themes as divergent a...

متن کامل

NICMOS Two Gyro Mode Coronagraphic Performance

In preparation for the Hubble Space Telescope (HST) entry into Two Gyro Mode (TGM) operations, the NICMOS coronagraphic performance was assessed during the February 21, 2005 TGM on orbit test (ID: 10448) in two filter bands (F110W and F160W). The gyroscope pair 2-4 was used for the TGM test. Observations were obtained of a previously observed calibration target (GJ517; sp.type=K5Ve) coronagraph...

متن کامل

C . Hines ( Space Science Institute ) & Glenn Schneider ( Steward Observatory )

We present results from our recent program (GO 9768: Hines PI ) to evaluate, calibrate, and enable for commissioning, high-contrast near-IR imaging polarimetry via coronagraphy with the Near Infrared Camera & Multi-Object Spectrometer (NICMOS) onboard the Hubble Space Telescope (HST). We find that the NICMOS Camera 2 polarizing filters can be used efficiently and effectively in combination with...

متن کامل

Coronagraphy with NICMOS

The Near Infrared Camera and Multi-Object Spectrometer (NICMOS) provides a coronagraphic imaging capability in camera 2. NICMOS PSF-subtracted coronagraphy routinely results in per-pixel background rejections of ∼ 10 of an occulted target’s total flux density at an angular distance of 1′′, thus providing a highcontrast lever for the detection of close sub-stellar companions. At 1.1 μm (with an ...

متن کامل

Polarimetry with NICMOS

NICMOS cameras 1 and 2 (with ∼ 43 and ∼ 76 mas/pixel, respectively) each carry a set of three polarizing elements to provide high sensitivity observations of linearly polarized light. The polarizers are bandpass limited and provide diffraction-limited imaging in camera 1 at 0.8 1.3μm, and in camera 2 at 1.9-2.1μm. The NICMOS design specified the intra-camera primary axis angles of the polarizer...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002