Microdome-gooved Gd(2)O(2)S:Tb scintillator for flexible and high resolution digital radiography.
نویسندگان
چکیده
A flexible microdome-grooved Gd(2)O(2)S:Tb scintillator is simulated, fabricated, and characterized for digital radiography applications. According to Monte Carlo simulation results, the dome-grooved structure has a high spatial resolution, which is verified by X-ray image performance of the scintillator. The proposed scintillator has lower X-ray sensitivity than a nonstructured scintillator but almost two times higher spatial resolution at high spatial frequency. Through evaluation of the X-ray performance of the fabricated scintillators, we confirm that the microdome-grooved scintillator can be applied to next-generation flexible digital radiography systems requiring high spatial resolution.
منابع مشابه
Investigating the capability of plastic scintillation detectors in design of a muon radiography system by Geant4 code
Imaging and identifying materials with high atomic numbers and densities, especially radioactive materials, is one of the issues that have been especially considered in recent years. Due to some limitations in conventional and old imaging techniques, finding an alternative method is very important. The cosmic muons with an infinite source are one of the sources that have been recently studied f...
متن کاملStructural and Optical Characterization of Luminescent (Y0.7Gd0.3)2O3:Eu Nanopowder and Translucent Ceramics
Phosphor nanomaterials are of special interest today due to their broad range of applications from the solid state lightening and novel flat displays to high resolution X-ray detectors and sensors in biomedicine. Among them polycrystalline Eu 3+ doped mixed oxide (Y 1-x Gd x) 2 O 3 is a well-known luminescent material widely used to provide red light emission for modern optoelectronic devices [...
متن کاملApplications of various imaging techniques in neutron radiography at BARC, Trombay
Neutron radiography systems based on Gd, Dy and In metallic foils and X-ray films have been used at this centre since early seventies for various NDT and R&D work in nuclear, defense and aerospace industries. In recent years use of digital detection systems such as neutron scintillator and CCD based imaging systems and photostimulated luminescence based phosphor imaging plate systems have been ...
متن کاملOptimization of phosphor-based detector design for oblique x-ray incidence in digital breast tomosynthesis.
PURPOSE In digital breast tomosynthesis (DBT), a volumetric reconstruction of the breast is generated from a limited range of x-ray projections. One trade-off of DBT is resolution loss in the projections due to non-normal (i.e., oblique) x-ray incidence. Although degradation in image quality due to oblique incidence has been studied using empirical data and Monte Carlo simulations, a theoretica...
متن کاملImage quality assessment in digital radiography systems- A Pehamed FLUORAD A+D phantom study
Introduction: The use of digital radiography systems has become more common all around the world. Ideal situation in radiography is to maximize the image quality while minimizing the patient dose. The purpose of this study was to compare image quality and radiation dose in different digital radiography systems. Materials and Methods: Images of Pehamed FLUORAD ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Optics express
دوره 18 14 شماره
صفحات -
تاریخ انتشار 2010