Diaphragm interference pattern EMG and compound muscle action potentials: effects of chest wall configuration.

نویسندگان

  • J Beck
  • C Sinderby
  • L Lindström
  • A Grassino
چکیده

The effect of chest wall configuration on the diaphragm electromyogram (EMGdi) was evaluated in five healthy subjects with an esophageal electrode for both interference pattern EMGdi (voluntary contractions) and electrically evoked diaphragm compound muscle action potentials (CMAPs). Diaphragm CMAPs (both unilateral and bilateral) were evaluated for the baseline-to-peak amplitude (Ampl), the time from the onset of the CMAP to first peak (T1), root mean square (RMS), and center frequency (CF) values of the CMAP power spectrum. CF values from the interference pattern EMGdi power spectrum were also calculated. For CMAPs obtained at an electrode position least influenced by variations induced by electrode positioning, Ampl increased with diaphragm shortening from functional residual capacity (FRC) to total lung capacity (TLC) by 101 and 98% (unilateral and bilateral, respectively). Bilateral CMAP RMS values increased 116% from FRC to TLC. CMAP T1 values decreased with diaphragm shortening from FRC to TLC by 1.1 and 2.1 ms for the unilateral and bilateral stimulations, respectively, and CF increased for the bilateral diaphragm CMAPs with diaphragm shortening. CF values from the interference pattern EMGdi did not show any consistent change with chest wall configuration. Thus CF values of the interference pattern EMGdi obtained with an esophageal electrode can be considered reliable for physiological interpretation, at any diaphragm length (if electrode positioning and signal contamination are controlled for), contrary to the diaphragm CMAPs, which are sensitive to changes in chest wall configuration. It is speculated that the different results (over the effects of chest wall configuration on interference pattern EMGdi and diaphragm CMAPs) amy be because of summation properties of the signals and how these influence the EMG power spectrum.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Parasternal intercostal and diaphragm function during sleep.

Action of the uppermost medial internal intercostal muscles-the parasternals-during rapid eye movement (REM) is uncertain; no direct recordings exist of shortening of these muscles during sleep. Historically, motor inhibition of skeletal muscles during REM sleep is thought to cause global loss of chest wall muscle function, REM "atonia," with preservation of only diaphragm function. However, re...

متن کامل

Diaphragm electromyogram in infants with abdominal wall defects and congenital diaphragmatic hernia.

Measurement of the diaphragm electromyogram (EMGdi) elicited by phrenic nerve stimulation could be useful to assess neonates suffering from respiratory distress due to diaphragm dysfunction, as observed in infants with abdominal wall defects (AWD) or congenital diaphragmatic hernia (CDH). The study aims were to assess the feasibility of recording EMGdi using a multipair oesophageal electrode ca...

متن کامل

Diaphragm EMG measured by cervical magnetic and electrical phrenic nerve stimulation.

The purpose of the study was to compare electrical stimulation (ES) and cervical magnetic stimulation (CMS) of the phrenic nerves for the measurement of the diaphragm compound muscle action potential (CMAP) and phrenic nerve conduction time. A specially designed esophageal catheter with three pairs of electrodes was used, with control of electrode positioning in 10 normal subjects. Pair A and p...

متن کامل

Neural respiratory drive in healthy subjects and in COPD.

The aim of the present study was to use the diaphragm electromyogram (EMG(di)) to compare levels of neural respiratory drive (NRD) in a cohort of healthy subjects and chronic obstructive pulmonary disease (COPD) patients, and to investigate the relationship between NRD and pulmonary function in COPD. EMG(di) was recorded at rest and normalised to peak EMG(di) recorded during maximum inspiratory...

متن کامل

Effects of lung volume on diaphragm EMG signal strength during voluntary contractions.

The use of esophageal recordings of the diaphragm electromyogram (EMG) signal strength to evaluate diaphragm activation during voluntary contractions in humans has recently been criticized because of a possible artifact created by changes in lung volume. Therefore, the first aim of this study was to evaluate whether there is an artifactual influence of lung volume on the strength of the diaphra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 82 2  شماره 

صفحات  -

تاریخ انتشار 1997