چکیده

PURPOSE To increase the efficiency of retinal image grading, algorithms for automated grading have been developed, such as the IDx-DR 2.0 device. We aimed to determine the ability of this device, incorporated in clinical work flow, to detect retinopathy in persons with type 2 diabetes. METHODS Retinal images of persons treated by the Hoorn Diabetes Care System (DCS) were graded by the IDx-DR device and independently by three retinal specialists using the International Clinical Diabetic Retinopathy severity scale (ICDR) and EURODIAB criteria. Agreement between specialists was calculated. Results of the IDx-DR device and experts were compared using sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV), distinguishing between referable diabetic retinopathy (RDR) and vision-threatening retinopathy (VTDR). Area under the receiver operating characteristic curve (AUC) was calculated. RESULTS Of the included 1415 persons, 898 (63.5%) had images of sufficient quality according to the experts and the IDx-DR device. Referable diabetic retinopathy (RDR) was diagnosed in 22 persons (2.4%) using EURODIAB and 73 persons (8.1%) using ICDR classification. Specific intergrader agreement ranged from 40% to 61%. Sensitivity, specificity, PPV and NPV of IDx-DR to detect RDR were 91% (95% CI: 0.69-0.98), 84% (95% CI: 0.81-0.86), 12% (95% CI: 0.08-0.18) and 100% (95% CI: 0.99-1.00; EURODIAB) and 68% (95% CI: 0.56-0.79), 86% (95% CI: 0.84-0.88), 30% (95% CI: 0.24-0.38) and 97% (95% CI: 0.95-0.98; ICDR). The AUC was 0.94 (95% CI: 0.88-1.00; EURODIAB) and 0.87 (95% CI: 0.83-0.92; ICDR). For detection of VTDR, sensitivity was lower and specificity was higher compared to RDR. AUC's were comparable. CONCLUSION Automated grading using the IDx-DR device for RDR detection is a valid method and can be used in primary care, decreasing the demand on ophthalmologists.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Short Report: Complications Delay in diabetic retinopathy screening increases the rate of detection of referable diabetic retinopathy

AIMS To assess whether there is a relationship between delay in retinopathy screening after diagnosis of type 2 diabetes and level of retinopathy detected. METHODS Patients were referred from 88 primary care practices to an English National Health Service diabetic eye screening programme. Data for screened patients were extracted from the primary care databases using semi-automated data colle...

متن کامل

Planning and Developing Services for Diabetic Retinopathy in Sub-Saharan Africa

Background Over the past few decades diabetes has emerged as an important non-communicable disease in SubSaharan Africa (SSA). Sight loss from Diabetic Retinopathy (DR) can be prevented with screening and early treatment. The objective of this paper is to outline the required actions and considerations in the planning and development of DR screening services.   Methods A multiple-case study app...

متن کامل

Automated Multi-Lesion Detection for Referable Diabetic Retinopathy in Indigenous Health Care

Diabetic Retinopathy (DR) is a complication of diabetes mellitus that affects more than one-quarter of the population with diabetes, and can lead to blindness if not discovered in time. An automated screening enables the identification of patients who need further medical attention. This study aimed to classify retinal images of Aboriginal and Torres Strait Islander peoples utilizing an automat...

متن کامل

Evaluation of Diabetic Retinopathy in Patients without Eye Complaints Referring to Imam Sadegh Hospital

OBJECTIVE: This research was conducted to evaluate the prevalence of diabetic retinopathy (DR) in patients who were unaware of their eye condition. MATERIALS AND METHODS: A descriptive cross-sectional study was performed in a 12-month period on patients who were referred to Meybod Imam Sadegh Diabetes Center. 152 patients who had no eye complaint were selected. Pupil dilation was created by C...

متن کامل

Evaluation of a System for Automatic Detection of Diabetic Retinopathy From Color Fundus Photographs in a Large Population of Patients With Diabetes

OBJECTIVE To evaluate the performance of a system for automated detection of diabetic retinopathy in digital retinal photographs, built from published algorithms, in a large, representative, screening population. RESEARCH DESIGN AND METHODS We conducted a retrospective analysis of 10,000 consecutive patient visits, specifically exams (four retinal photographs, two left and two right) from 5,6...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 96  شماره 

صفحات  -

تاریخ انتشار 2018