Cutoff and reestablishment of current in rocket-triggered lightning
نویسندگان
چکیده
[1] A total of three negative rocket-triggered lightning flashes without return strokes (two from 1997 and one from 1993) are analyzed in this paper in order to study the processes associated with the disintegration of the triggering wire and its replacement by an airplasma channel. It appears that the gap resulting from the vaporization of the triggering wire by the upward-positive leader current is bridged by a leader/return-stroke type process. Electric fields at distances of 50, 110, and 500 m, the corresponding magnetic fields at 500 m, and the currents to ground are examined for the two 1997 flashes. The electric field prior to the triggering wire’s vaporization in these flashes exhibits a positive (atmospheric electricity sign convention) millisecond-scale ramp due to the upwardextending positive leader. The electric field changes observed at the three distances just prior to wire vaporization are consistent with an equivalent point charge of about 0.3 C at a height of 1.2 to 1.5 km, suggesting that the charge density distribution at that time is strongly skewed toward the upward positive leader tip. The length of the triggering wire at the time of its vaporization was estimated from still photographs to be about 210–220 m. Following the ramp, a microsecond-scale V-shaped negative pulse, which resembles the close electric field signature of a small dart-leader/return-stroke sequence, is observed. The corresponding magnetic field decreases abruptly, simultaneously with the onset of the leading edge of the V-shaped pulse, to values near zero and remains there for tens of microseconds, indicating the attempted interruption (cutoff) of the upward positive leader current flow to ground through the triggering wire as it is vaporized by this current. Following the abrupt decrease, the magnetic field exhibits a rapid increase at a time corresponding to the trailing edge of the V-shaped electric field pulse, suggesting that the vaporized triggering wire is replaced by an air-plasma channel that becomes part of the upward positive leader channel when electrical connection to ground is restored. For the third triggered lightning flash, from 1993, similar inferences regarding the processes involved in the replacement of the triggering wire by an air-plasma channel are made from high-speed (streak) photography and from measurements of the current to ground and electric field at 30 m. In this flash, the upward positive leader exhibited very pronounced stepping: step current pulses had peaks, as measured at the ground, that were up to a few kiloamperes, and step charges that were up to 100 mC. Characterization of the attempted interruption and the following reestablishment of current to ground in rocket-triggered lightning may have important implications for the understanding of channel current cutoff in natural lightning flashes and may provide new insights into the formation of strokes observed to occur in the same channel within a millisecond or less.
منابع مشابه
A review of ten years of triggered-lightning experiments at Camp Blanding, Florida
The principal results of triggered-lightning experiments conducted at the International Center for Lightning Research and Testing (ICLRT) at Camp Blanding, Florida, from 1993 through 2002 are reviewed. These results include (a) characterization of the close lightning electromagnetic environment, (b) first lightning return-stroke speed profiles within 400 m of ground, (c) new insights into the m...
متن کاملInitial stage in lightning initiated from tall objects and in rocket- triggered lightning
[1] We examine the characteristics of the initial stage (IS) in object-initiated lightning derived from current measurements on the Gaisberg tower (100 m, Austria), the Peissenberg tower (160 m, Germany), and the Fukui chimney (200 m, Japan) and their counterparts in rocket-triggered lightning in Florida. All lightning events analyzed here effectively transported negative charge to ground. For ...
متن کاملReturn stroke peak current versus charge transfer in rocket‐triggered lightning
[1] We examined data on 117 return strokes in 31 rocket‐and‐wire‐triggered lightning flashes acquired during experiments conducted from 1999 through 2004 at the International Center for Lightning Research and Testing at Camp Blanding, Florida, in order to compare the peak currents of the lightning return strokes with the corresponding charges transferred during various time intervals within 1 m...
متن کاملCharacterization of return-stroke currents in rocket-triggered lightning
[1] We present a statistical analysis of the salient characteristics of current waveforms for 206 return strokes in 46 rocket-triggered lightning flashes. The flashes were triggered during a variety of experiments related to the interaction of lightning with power lines that were conducted from 1999 through 2004 at the International Center for Lightning Research and Testing at Camp Blanding, Fl...
متن کاملCharacterization of Pulses Superimposed on the Initial Continuous Current of Upward Lightning
We compare the characteristics of initial continuous current pulses (ICC pulses) in natural upward lightning as observed on the Gaisberg tower (100 m), the Peissenberg tower (160 m), and the Fukui chimney (200 m) with their counterparts in rocket-triggered lightning in Florida. All lightning events analyzed here effectively transported negative charge to ground. The geometric mean (GM) values o...
متن کامل