The Impact of Airtightness On System Design
ثبت نشده
چکیده
Air pressure acting on building envelopes can wreak havoc with building performance if not properly understood and adequately designed for. Uncontrolled air pressure across the building envelope and within the building itself can cause infiltration and exfiltration that overpower HVAC systems. By disrupting the HVAC design, pressures can cause discomfort and create infection control and indoor air quality problems. In heating climates, exfiltrating air carries with it water vapor and lost energy. The water vapor condenses and causes many problems, from wetting to bacterial growth and deterioration of the building envelope. In cooling climates, water vapor is carried in with the infiltrating air, causing condensation, mold, and bacterial growth. Moisture-laden air can travel within interstitial spaces due to negative pressures inside those spaces. The moisture can condense in strange places like interior walls and ceilings that are connected to the building envelope.
منابع مشابه
Airtightness and ventilation in a mild climate country rehabilitated social housing buildings ¬タモ What users want and what they get
Dwellings should be designed for users' wellbeing but frequently their actions seem to contradict the logic adopted in the design. The impact of users' actions and habits on buildings energy efficiency is well established and documented. However, there is a lack of available information concerning the relationship between user behaviour, building airtightness and ventilation. This paper explore...
متن کاملAnalysis of the Impact of Managed Pressure Drilling Technology on Current Casing Program Design Methods (TECHNICAL NOTE)
This paper analyzed the characteristics of managed pressure drilling (MPD) technology and impact of wellhead back pressure on the wellbore annulus pressure profile, and found that the application of this technology provides room for improvement to the current casing program design. Meanwhile, the equivalent density of drilling fluid in wellbore annulus needs to consider the impact of back press...
متن کاملAirtightness, Ventilation, and Energy Consumption in a Manufactured House: Pre-Retrofit Results
A retrofit study is being conducted to investigate the airtightness, ventilation and energy impacts of tightening the exterior envelope and the heating and air conditioning system ductwork of a double section manufactured house. This report describes the results of the pre-retrofit assessment of building airtightness, ventilation, and energy consumption under both heating and cooling conditions...
متن کاملMechanical Air Distribution and Interacting Relationships
It has been determined from extensive testing conducted between May 1987 and May 1988, in the hot and humid climate of central Florida, that pressure differences within the envelope of residential housing exists. These can range from near neutral to pressures, either positive or negative, as great as 0.24" W.C. (60 pascals). Reasons sighted and discussed in this paper include duct system design...
متن کاملRe-Framing the Knowledge to Action Challenge Through NIHR Knowledge Mobilisation Research Fellows; Comment on “CIHR Health System Impact Fellows: Reflections on ‘Driving Change’ Within the Health System”
The ambition of the Canadian Institutes for Health Research Health System Impact (HSI) Fellowship initiative to modernise the health system is impressive. Embedded researchers who work between academia and nonacademic settings offer an opportunity to reframe the problem of evidence uptake as a product of a gap between those who produce knowledge and those who use it. As such, there has been an ...
متن کاملThe Impact of Rational Governance on the Financial Performance of Industrial Companies Sample (Pharmaceutical Companies) Listed in Amman Stock Exchange
The study aimed to determine the impact between rational governance and financial performance on a sample of pharmaceutical companies listed in the Amman Stock Exchange. The questionnaire was used to collect data, where (200) inquiries were received (170) valid for statistical analysis were excluded (10) where used in Analysis process (160) of the total questionnaires distributed and to achieve...
متن کامل